5.2 Installation and connection

CAUTION!
The installation and maintenance of the appliance should only be carried out by
trained personnel!
Installation
Discard the complete packing material after unpacking the device.
Place the device on top of an even and safe surface which supports the weight of the
device and is not heat sensitive.
Not at any time should you place the device on an inflammable surface.
You must not position the device near open fireplaces, electric ovens/arc furnaces,
furnaces/electric heaters or other heat sources.
Install the device in a well ventilated area.
Place the device in a way, so that the ventilation openings at the back are not
covered or blocked.
The convection oven Steamer may only be
placed on top of a base frame specially
designed for this purpose.
So not place the device directly at walls or
other objects that are made of combustible
materials. Keep a minimum distance of
100 mm between walls or other objects and
the right side, back and top of the device.
Keep a minimum distance of 500 mm to the
left side of the device and other objects.
(Figure 1).
The levelling and height adjustment using
the adjustable legs should be performed as
shown in Figure 2.
Harsh differences in height or level may
affect the functioning of the device.
Remove the protective foil from the outer
panels. Slowly pull these off so that no glue
or adhesive residuals remain.