CONTACT
32(AP)
28(COM)
32(AP)
28(COM)
33(ORO)
34(COM)
33(ORO)
34(COM)
ENC1
ENC2
LED LIGHT
LOCKS
RECEIVER CARD
B71/BCHP
BI/BCHP
BATTERY CHARGER
BI/BAT/KIT
BATTERY KIT
2x12 Vdc 4.5 Ah
(AGM type ONLY)
72
DESCRIPTION
Open command input (NO).
The command input (N.C.) available for the connection of the sensor of the ACS/BA/60 detachable
When the ACS/BA/60 detachable boom safety system intervenes, the contact switches from N.C.
to N.O.
Enable the contact via parameter
Clock timer contact input (N.O.).
When the clock function is active, the barrier opens and remains open.
At the end of the programmed time set with the external device (clock) the barrier closes.
The function of this command is determined by parameter
The command input (N.C.) available for the connection of the sensor of the ACS/BA/60 detachable
When the ACS/BA/60 detachable boom safety system intervenes, the contact switches from N.C.
to N.O.
Enable the contact via parameter
For systems composed of two MASTER and SLAVE opposing barriers, connect the detachable boom
coupling system sensor of the SLAVE barrier STRICTLY to the ORO input of the SLAVE control unit.
WARNING! Always disconnect from electrical power before disconnecting or connecting the encoder
cable.
WARNING! Always disconnect from electrical power before disconnecting or connecting the encoder
cable.
Connector for the (OPTIONAL) B73/EXP
Connectors for connecting lock device microswitch and safety stop microswitch on barrier inspection
Jumper the other connector if only one connector is connected.
Connector for slot-in radio receiver board.
–
–
Connector for slot-in battery charger board.
In the event of a mains power loss, the controller unit is powered by the batteries. When battery power
is used, the message
until mains power is restored or until the battery voltage drops below the minimum permissible limit.
In this case,
(Battery Low) is shown on the display and the controller unit accepts no commands.
If mains power is lost while the boom is moving, the boom stops and then automatically resumes the
interrupted manoeuvre after 2 seconds.
By setting parameter
to a value different than
parameter
the battery operation limitation type is enabled when the voltage drops under a certain
threshold.
Parameter
is not available for SLAVE automation systems.
WARNING! the batteries must always be connected to the electronic controller unit in order to charge.
Periodically (at least every 6 months), check that the batteries are in good working order.
For more information, refer to the installation manual for the B71/BCHP or BI/BCHP battery charger.
.
.
.
, the battery management is enabled. With