Télécharger Imprimer la page

Olimpia splendid DOLCECLIMA AIR PRO Mode D'emploi Et D'entretien page 61

Masquer les pouces Voir aussi pour DOLCECLIMA AIR PRO:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
4.2.b
Error codes
During the appliance functioning, a few anomalies which stop its functioning could appear.
In these cases, some error codes appear on the control panel.
• P1 Lower tray full.
• Empty it by operating as described in paragraph 4.2.a
-------------------------------------------------------------------
• F1 Filters cleaning.
• Message F1 appears every 250 hours of operation of the fan motor.
Proceed with the filters cleaning (paragraphs 4.1.b - 4.1.c - 4.1.d) and reset the hours counting by
keeping key "ON/OFF" on the appliance control panel pressed for 5 seconds.
-------------------------------------------------------------------
• E1 Environment temperature sensor error.
• E2 Evaporator temperature sensor error.
• E3 Condenser temperature sensor error
• E4 Display panel communication error.
In these cases:
a. electrically disconnect the appliance
b. wait a few minutes
c. connect the plug to the power socket
d. restart the appliance.
If the inconvenience persists and the error code doesn't turn off, electrically disconnect the
appliance and refer to an Assistance Centre.
5 - TECHNICAL DATA
For the technical data, please consult the data plate applied to the product (Fig.2).
• Dimensions (W x H x D)
• Working temperature limits in Cooling function
• Working temperature limits in Dehumidification
function
• Working temperature limits in Heating mode
(heat pump)
• Refrigerant gas
6 - WIRING DIAGRAM
The wiring diagram shown in image 35.
This symbol indicates the element is optional.
OPTIONAL
490 x 765 x 425 mm
17°C÷35°C (62 F ÷ 95 F)
13°C÷35°C (55 F ÷ 95 F)
5°C÷30°C (41 F ÷ 86 F)
R290
DOLCECLIMA AIR PRO
EN - 23