2.4 - FIXED INSTALLATION
The air conditioner can also be installed with fixed holes in windows or walls. Air flow must not be obstructed
by protective mesh or similar. Any forms of protection must have a total cross-section for air flow of not less
than 140 cm
.
2
a. Position the machine side terminal (2) on the flexible hose (1) as shown by Fig.8.
b. Drill a 127 mm hole in the glass or in the wall at a height above the floor included between 300 and 1200
mm (Fig.13).
c. Position the terminal (7) in the wall hole and mark the drilling points (Fig. 14-a, 14-b).
d. Remove the terminal (7) and drill 6 mm holes (Fig. 14-c, 14-d).
e. Insert the supplied wallplugs (10) in the holes (Fig. 14-e).
f. Position the terminal (7) in the hole of the wall and fix it with the supplied screws (10) (Fig. 14-f, 14-g).
g. Insert the machine side terminal (2) on the air outlet grid of the appliance (36) as shown in figure 9.
h. Connect the other extremity of the flexible hose (1) on the terminal (7) (Fig.14-i).
i. Close the cap (7a) when the appliance is not running (Fig.14-h).
2.5 - ELECTRICAL CONNECTION
The appliance is fitted with a power cable with plug.
Before connecting the air conditioner ensure that:
• The voltage and power frequency values match those specified on the
appliance plate data.
• The power line is equipped with an effective earth connection and is
correctly sized for maximum power consumption of the air conditioner.
• The appliance's power network must be equipped with a suitable
omnipolar disconnection device compliant with national installation
regulations.
• The appliance is powered solely through a socket compatible with the plug provided.
CAUTION
Any replacement of the power cable must be carried out solely by Olimpia Splendid
technical support or by similarly qualified personnel.
2.6 - DRAINAGE
Depending on the modality of use of the appliance, it is necessary to connect the condensation discharge pipe.
2.6.a - Use as dehumidifier
For the correct use of the appliance, work as follows (figures 29 and 32):
a. Remove the cap (28).
b. Insert the supplied pipe (12) in the connector.
Make sure the end of the discharge pipe (12) is positioned on a drain well or in a container.
Make sure the pipe (12) is not clogged.
c. If necessary, apply the terminal (13) to the condensation discharge pipe (12).
2.6.b - Use as heat pump
(only for the suitable version)
For the correct use of the appliance, work as follows (figures 30 and 33):
a. Remove the cap (35).
b. Insert the supplied pipe (12) in the connector.
Make sure the end of the discharge pipe (12) is positioned on a drain well or in a container.
Make sure the pipe (12) is not clogged.
c. If necessary, apply the terminal (13) to the condensation discharge pipe (12).
EN - 13
DOLCECLIMA AIR PRO