6

TECHNICAL DATA

6.1

Operating Conditions

WARNING!
Risk of injury
Malfunction if used outside!
▶ Do not use Type 6126 and Type 6606 outdoors and avoid heat
sources which may cause the allowable temperature range to
be exceeded.
Allowable temperatures
Ambient temperature:
Medium temperature:
Media:
neutral and aggressive, gaseous and liquid
media which do not attack body and seal
materials
see Bürkert Chemical Resistance Chart
(www.burkert.com)
Protection class:
IP65 with flying leads or cable plug
IP40 with rectangular plug
max. +55 °C
-5... +50 °C
6.2
Conformity
CE mark conforms to EMC Directive 2004/108/EEC
(only if cables, plugs and sockets connected correctly).
6.3

Mechanical data

Dimensions
See data sheet
Body material
PPS, PVDF, ETFE, PEEK
Brass, stainless steel
Seal material
FKM, FFKM, EPDM