6
TECHNICAL DATA
6.1
Operating Conditions
WARNING!
Risk of injury
Malfunction if used outside!
▶ Do not use Type 6126 and Type 6606 outdoors and avoid heat
sources which may cause the allowable temperature range to
be exceeded.
Allowable temperatures
Ambient temperature:
Medium temperature:
Media:
neutral and aggressive, gaseous and liquid
media which do not attack body and seal
materials
see Bürkert Chemical Resistance Chart
(www.burkert.com)
Protection class:
IP65 with flying leads or cable plug
IP40 with rectangular plug
max. +55 °C
-5... +50 °C
6.2
Conformity
CE mark conforms to EMC Directive 2004/108/EEC
(only if cables, plugs and sockets connected correctly).
6.3
Mechanical data
Dimensions
See data sheet
Body material
PPS, PVDF, ETFE, PEEK
Brass, stainless steel
Seal material
FKM, FFKM, EPDM
english
7