Insert the seal into the valve.
NOTE!
If the tightening torque is too great, the device may be
damaged!
Observe the maximum tightening torque of the screws!
→
Attach valve to manifold:
Screw in screws at 0.3 ± 0.05 Nm.
Screws for man-
ifold
Tightening torque:
0.3 ± 0.05 Nm
Seal
Manifold
0.1 ± 0.05 Nm
Tighten screws alternately, in two
steps:
1st step:
Tightening torque 0.1 ± 0.05 Nm
2nd step:
Tightening torque 0.2 ± 0.05 Nm
→
Attach coil to body.
english
1st step
2nd step
1
3
2
4
0.2 ± 0.05 Nm
13