5.
general infOrmaTiOn
5.1. contact address
germany
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: info@de.buerkert.com
international
Contact addresses can be found on the final pages of
these operating instructions.
And also on the internet at:
www.burkert.com
5.2. Warranty
The warranty is only valid if the device is used as authorized
in accordance with the specified application conditions.
5.3. information on the internet
The operating instructions and data sheets for Type 0293 can
be found on the Internet at:
www.burkert.com
english
8
6.4. dirt trap
The necessary dirt trap is integrated into the valve.
6.5. mechanical data
Dimensions
see data sheet
Body material
Brass
Sealing material
NBR
6.6. fluidic data
Circuit functions
A
A
(NC)
P
Pressure range
according to the design (see
rating plate)
Note the voltage and current type as specified on
the rating plate.
english
10
2/2-way valve, direct-
acting, normal output A
unloaded
6.
Technical daTa
6.1. Operating conditions
Permitted medium and
ambient temperature:
Max. operating pressure:
Permitted media depending on seal material:
Seal material
NBR
Valve group 2, Class A:
Fuel gases of the 1st, 2nd and 3rd gas
family.
Protection class:
6.2. conformity
The device conforms to the EC directives according to the
EC Declaration of Conformity.
6.3. standards
The conformity with EC guidelines is guaranteed in accor-
dance with standards:
• EN 61010-1, EN 50178, EN 60664-1, EN 60204-1,
EN 161
6.7. rating plate
Orifice
Operating principle
Type
0293 A 25,0 NBR MS
Rp1
P N 0 - 0.15 bar
~230 V 50 Hz 32 VA
CE - 0085AS0390
KL: A GR: 2 -15 °C +60 °C
00189398
Id.- Number
EC Examination Certificate,
Protection class, Classification,
Temperature range
Voltage, Frequency, Power
consumption
Port connection, Nominal pressure
Type 0293
-15 ... +60 °C
0.15 bar
Permitted media
IP65 in accordance with
device socket
english
Seal material
Housing material
IP65
W15 ML
english
11
9