Initial Testing; Maintenance; Disposal - Roger Technology B70/2ML Instructions Et Consignes Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 111
POSITION RECOVERY WITH CONTROL UNIT NOT POWERED (BLACK OUT) AND INTERMEDIATE POSITION OF
LEAVES (NOT COMPLETELY CLOSED OR NOT COMPLETELY OPEN)
At the next command, the gate leaves perform the opening manoeuvre at low speed to restore normal operating mode.
repositioning procedure begins, which will be completed when the leaves have performed a complete run without
interruption.
18

Initial testing

The installer is required to measure impact forces and select on the control unit the appropriate speed and torque
12445.
Make sure that the provisions in Chapter 1 "GENERIC WARNINGS are observed.
• Turn on the power supply.
• Check that the automation system motors rotate in the correct direction. If the leaves do not move correctly, swap
• Check that all connected controls are working correctly.
• Check travel and deceleration.
• Check that the impact force is correct, in compliance with EN 12453 and EN12445.
• Check that the safety devices are activated correctly.
gate leaves must not move.
• If the battery kit is installed, disconnect from mains and check that the batteries are working.
• Disconnect from mains power and disconnect the batteries (if used), then reconnect. Check the correct completion
of the position recovery phase when opening and when closing.
19

Maintenance

Perform scheduled maintenance every 6 months.
Check cleanliness and function.
If the unit contains dirt, moisture, insects or other foreign matter, disconnect from mains power and clean the board
and the housing.
Repeat the initial installation test procedure after cleaning.
If any corrosion is found on the printed circuit board, evaluate if it is necessary to replace the board itself.
Check that the battery is in good working order.
20

Disposal

The
removing the product correctly and safely. This product consists of numerous different materials. Some of
management facilities indicated by local legislation applicable for this category of product.
Do not dispose of this product as domestic refuse. Observe local legislation for differentiated refuse collection, or hand
the product over to the vendor when purchasing an equivalent new product.
product may contain substances that are harmful to the environment or dangerous and which may cause damage to
the environment or health risks if disposed of incorrectly.
78
and a blackout occurs, when the mains voltage returns, in whatever position the leaves are,
is at
, upon receipt of a command, the
Warning! Some parts of this