Roger Technology B70/2ML Instructions Et Consignes Pour L'installateur page 70

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 111
Selecting the type of photocell test on input FT1
This parameter is visible if
If the photocell test is enabled, the control unit will check the photocells connected to input FT1 are working properly.
Selecting the type of photocell test on input FT2
This parameter is visible if
If the photocell test is enabled, the control unit will check the photocells connected to input FT2 are working properly.
Photocell test disabled.
Photocell test enabled on opening ONLY.
Photocell test enabled on closure ONLY.
Photocell test enabled on both opening and closure.
operating the clock or sensing edge.
Setting motor stop distance
Select number of motors installed
1 motor.
NOTE: This parameter is visible only if par.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when opening.
Contact with 8k2 resistor. The gate reverses only when opening.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate reverses only when
opening.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate always reverses.
STEP MODE.
PARTIAL OPENING
OPENING
CLOSING.
STOP.
Courtesy light. The output COR is managed from the remote control. The light remains lit as long as the remote control
is active. The parameter 79 is ignored.
The remote control turns the courtesy light on and off. The parameter 79 is ignored.
70
8k2
N.C.
8k2
or
is set.
or
is set.
COS
(1)
(1)
(1)
N.C.
8k2
8k2
)
)
is
(1)
8k2
8k2
8k2

Publicité

Table des Matières
loading

Table des Matières