Roger Technology B70/2ML Instructions Et Consignes Pour L'installateur page 50

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 111
necessary, also checked.
requirements for the operation of automatic doors and gates. In particular, these
standards require the use of force limiting and safety devices (sensing ground
or objects in the operating area and prevent collisions in all circumstances.
The installer is required to measure impact forces and select on the control
unit the appropriate speed and torque values to ensure that the door or gate
ROGER TECHNOLOGY cannot be held responsible for any damage or injury
caused by the installation of incompatible components which compromise the
safety and correct operation of the device.
the maximum stop distance or the alternative use of the rubber deformable
edge, the closing speed or the gate and in general all aspects indicated by
the applicable regulations. Moreover, please not that if the command means
control and operation and the command type and the use type must comply
type A or B command or type 1 or 2 use).
range of action of the automation system's moving parts; the direct commands
must be installed at a minimum height of 1.5 m and must not be accessible to
the public; moreover, unless the device is key operated, they must be located
with a direct view to the motorised part and far from the moving parts.
dangerous areas.
Each installed device must have a visible indication of the motorised door or
subsequent revisions
OFF position and disconnect any buffer batteries before performing any
cleaning or maintenance operations.
Ensure that an adequate residual current circuit breaker with a 0.03 A threshold
installation in accordance with best practices and in compliance with applicable
legislation.
When requested, connect the automation to an effective earthing system that
complies with current safety standards.
with grounding wire.
Only use original spare parts when repairing or replacing products.
The installer must provide the user with complete instruction for using the
motorised door or gate in automatic, manual and emergency modes, and must
50

Publicité

Table des Matières
loading

Table des Matières