Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached, the gate closes
automatically. The timer count restarts if a photocell is triggered.
IMPORTANT: persistent activation of the opening command prevents automatic reclosure; the automatic reclosure time
count is resumed when the opening command is released.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Enabling of management for opening with automatic reclosure exclusion
if you set
, automatic reclosure is excluded following an AP command, but it is activated following a PP or PED
command.
NB:
Disabled.
An AP (opening) command activates the opening manoeuvre. With the gate fully open, automatic reclosure is excluded.
An AP (open) or CH (close) command activates the closure manoeuvre.
A PP (step mode) command activates the opening manoeuvre. With the gate fully open, automatic reclosure is exclu
ded. Another PP (step mode) command activates the closure manoeuvre.
A PED (partial opening) command activates the partial opening manoeuvre. Automatic reclosure is excluded. Another
PED (partial opening) command activates the closure manoeuvre.
Adjusting opening delay (alignment) of MOTOR 2
During opening, MOTOR 2 starts with an adjustable delay after MOTOR 1.
From 0 to 10 s.
Adjusting closing delay (alignment) of MOTOR 1
During closing, MOTOR 1 starts with an adjustable delay after MOTOR 2.
From 0 to 30 s.
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention)
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection system.
From 0 to 60 s.
Electric lock mode selection
Normally UNPOWERED electric lock (powered only for 3 s when opening starts).
N.B.
"ventouse" type electric block (normally powered when the gate is completely closed). Not powered when gate is moving.
"ventouse" type electric block (normally powered when the gate is completely opened or completely closed). Not powe
red when gate is moving.
Electric lock of normally NOT powered type, with adjustable timing
=0.5 seconds;
=1 second;
Enable electric lock
Disabled.
Enabled. When LEAF 1 approaches the gate closed stop, the controller delivers supplementary power to MOTOR 1 to
latch the electric lock.
Enabled. When LEAF 1 approaches the gate closed stop, the controller delivers maximum power to MOTOR 1 to latch
the electric lock. The obstacle detection system is disabled.
Setting motor torque
Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
ONLY for particularly lightweight installations not exposed to severe weather conditions (strong
winds or very cold temperatures). In installations with gate leaves of different lengths, they torque value may be set
separately, setting a value for parameter
= 0%.
= +8%;
= +16%;
= +25%;
.
=1.5 seconds.
between
and
.
(reduced motor torque = increased sensitivity).
= +35% (increased motor torque = reduced sensitivity).