Wiring Diagram - Sime BRAVA ONE BF Serie Manuel Pour L'utilisation, L'installation Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
5.11

Wiring diagram

BROWN
V
BLUE
PI
BLACK
BROWN
L
N
BLUE
CN11
EAR
Line
L
Neutral
N
F
Fuse (3.15AT - 250V)
Ignition transformer
TRA
System pump
PI
V
Fan
Ignition / Detection electrode
EAR
Gas solenoid valve
EV
Domestic hot water sensor
SS
Dual sensor (thermal safety/delivery)
SM1-2
To connect the "Air Thermostat" or, alternatively the "Remote Control", remove the bridge
between terminals 5-6.
m
CAUTION
Users must:
– Use an omnipolar cut-off switch, disconnect switch
in compliance with EN Standards which ensures
complete cut-off in overvoltage category III conditions
(i.e. where there is at least 3 mm between the open
contacts)
.
– Respect the connections L (Live) - N (Neutral).
– Ensure that the special power cable is only replaced
with a cable ordered as a spare part and connected
by professionally qualified personnel.
VD
BLACK
2
3
EV
CN12
CN13
CN14
F
TRA
CR
SE
TA
6
5
4
3
CN15
CN3
CN5
CN6
Flow meter
FLM
Diverter valve
VD
PA
Water pressure switch
Air thermostat
TA
External sensor
SE
CR
Remote control (instead of air thermo-
stat)
m
CAUTION
Users must:
– Connect the earth wire to an effective earthing sys-
tem. The manufacturer is not responsible for any dam-
age caused by failure to earth the appliance or failure
to observe the information provided in the wiring dia-
grams
.
d
IT IS FORBIDDEN
To use water pipes for earthing the appliance.
SS
PA
FLM
SM1
SM2
Fig. 15
59

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Brava one 25 bfBrava one 30 bf8112100811210181121028112103

Table des Matières