Reassembling The Mask; Accessories /Replacement Parts - ResMed MIRAGE FULL FACE MASK 2 Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
2 Push the valve frame over the tabs of the
valve elbow until they lock together
(Fig. E-2). Make sure the valve frame and
valve elbow are securely connected to each
other.
3 Insert the swivel into the end of the valve
elbow and secure it with the swivel clip
(Fig. E-3).
R
EASSEMBLING THE
1 Check that the holes in the exhaust vent are
not obstructed. If they are obstructed,
replace the exhaust vent. Push the exhaust
vent onto the mask frame so the small round
bump on the exhaust vent is on the outside
of the mask frame (Fig. F-1).
2 Twist the luer lock port caps onto the mask
ports (Fig. F-2).
3 Insert the valve into the mask frame. Hold
the mask frame and the inserted valve firmly
together.
4 To attach the elbow retainer, fit one side of
the elbow retainer against the groove of the
valve. While holding one wing of the elbow
retainer down (Fig. F-3a), press the other
wing down until the elbow retainer clicks
into place (Fig. F-3b).
5 Rotate the elbow retainer to its original
position (Fig. F-4).
6 Check that you have fitted the valve and
elbow retainer correctly by firmly pulling the
valve away from the frame. If the valve is
fitted correctly, it should not separate from
the frame.
If the valve comes away from the frame, try
refitting the elbow retainer as described in
Steps 3 and 4. If the valve still comes away
from the frame when you pull on it, you may
need to replace the elbow retainer with a
new one.
7 Fit the grooved edge of the mask cushion to
the mask frame. Fit the top section first, then
work your way around the mask, pushing the
cushion onto the frame, ensuring a good seal
has been achieved.
Then push the cushion clip over the cushion
onto the mask frame, ensuring it clicks into
place in all locations (Fig. F-5).
M
ASK
8 Optional:
Optional: Attach the forehead pad clip
Optional:
Optional:
assembly to the top of the mask frame
(Figs. G-1 and G-2).
9 Thread the straps of the headgear through
the slots on the mask frame and fasten the
Velcro straps. The M
S
2 headgear label should face outwards
ERIES
and be near your neck when fitted.
Note:
Make sure the cord of the Quick Release
Tab is not worn or damaged. If it is damaged,
replace the entire headgear.
A
/R
CCESSORIES
EPLACEMENT
Part No.
Item
16659
Mirage Full Face Mask Series 2
System, Small, Standard
16660
Mirage Full Face Mask Series 2
System, Small, Shallow
16661
Mirage Full Face Mask Series 2
System, Medium, Standard
16662
Mirage Full Face Mask Series 2
System, Medium, Shallow
16663
Mirage Full Face Mask Series 2
System, Large, Standard
16664
Mirage Full Face Mask Series 2
System, Large, Shallow
16613
Anti-asphyxia valve (1 pk.)
16604
Cushion, Small, Standard (1 pk.)
16671
Cushion, Small, Shallow (1 pk.)
16605
Cushion, Medium, Standard (1 pk.)
16672
Cushion, Medium, Shallow (1 pk.)
16606
Cushion, Large, Standard (1 pk.)
16673
Cushion, Large, Shallow (1 pk.)
16674
Cushion clip, Small (1 pk.)
16675
Cushion clip, Medium (1 pk.)
16676
Cushion clip, Large (1 pk.)
16509
Exhaust vent (1 pk.)
16510
Exhaust vent (10 pk.)
16680
Headgear (1 pk.)
16681
Luer lock port caps (2 pk.)
16682
Luer lock port caps (10 pk.)
F
F
M
IRAGE
ULL
ACE
ASK
P
ARTS

Publicité