7.6.3 Resetting to factory setting

The device can be reset to the delivery condition. All parameters saved until now, such as the limit
switch positions, stop positions, door zone length, etc., are erased. Resetting is possible using a
compatible control, the external programming unit or a CANopen terminal. To reset to factory setting,
please refer to the programming manual.
EN - page 30 (R60953.0009 3)
After the reset of the stops, the UCM function must be checked again
(incl. braking distance for overall system).
A comprehensive acceptance test must be performed after resetting to
factory setting.