In the standard, the door zone is preset to ± 20 mm from the sill. It can be modifi ed between
± 5-200 mm. More detailed information on the parameters can be found in the programming
manual.
A maximum of 200 sills is possible. Sills must have a minimum distance of 20 mm from one another. If
neighboring door zones are overlapping, they will be shortened in order to have a zone-free area of at
least 10 mm, or they will be merged to a common zone.
2.2 Special features
• Mechanical limit switches are no longer necessary
• No additional magnets are necessary for the premature door opening
• Easy installation through hat rail assembly in the roof control or control boxes
2.3 Scope of delivery PSU01
• Evaluation Unit / Position Supervisor Unit in top-hat rail housing.
• Ants LES01 (separate instruction manual for Ants LES01 is included in the scope of delivery).
2.4 Example of a type plate
A label is attached to the Position Supervisor Unit. It includes the following information:
• order code
• SetID (sensor + Evaluation Unit)
• type designation / serial number
• certifi cate number TÜV
• power supply
• CE mark
• reference to operating instructions (address)
2.4.1 Evaluation Unit / Position Supervior Unit
2 <
Fritz Kübler GmbH
Schubertstraße 47
D-78054 Villingen-Schwenningen
2.4.2 Ants LES01
2
Fritz Kübler GmbH
Schubertstraße 47
D-78054 Villingen-Schwenningen
The redundant door zone relays (port X6) are exclusively intended
for an optional external UCM unit and may not be used for any other
elevator safety function.
8.PSU01.xxxx.xxxx
SetID: 00070-11/2018 S-No: XX3333XX
Type: PSU01
TÜV-A-AT-X-XX-XXXX-EUES
24 VDC PELV XXA
8.PSU01.xxxx.xxxx
SetID: 00070-11/2018 S-No: XX1234XX
Type: PSU01 (Ants LES01)
TÜV-A-AT-X-XX-XXXX-XXXX
0408
WH
BN
GN
YL
GND
+ 24
CAN
CAN
VDC
High
Low
EN - page 11 (R60953.0009 3)