Operating instructions
Electronic position indicator
and electronic frequency meter
CODIX 54P
1. Description
• 6-digit position indicator and frequency meter
• Red LED display, character height 14 mm
• Display range -199 999 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Position indicator operating modes
– Count input INP A + count direction input
INP B(Cnt.Dir)
– Differential count INP A - INP B (up.dn)
– Totalising INP A + INP B (up.up)
– Count Up/Down INP A 90° INP B x 1 (quad)
– Count Up/Down INP A 90° INP B x 2 (quad2)
– Count Up/Down INP A 90° INP B x 4 (quad4)
• Frequency meter
– Frequency input INP C
– Value conversion and display in 1/s or 1/min
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA.
1.1. Preface
Please read this instruction manual
entirely and carefully before installa-
tion and start-up. Please observe all
warnings and advice, both for your
own safety and for general plant
safety. If the device is not used in
accordance with this instruction
manual, then the intended protec-
tion can be impaired.
2. Safety Instructions and Warnings
Please use the device only if its
technical condition is perfect. It
should be used only for its intended
purpose. Please bear in mind safety
aspects and potential dangers and
adhere to the operating instructions
at all times.
Defective or damaged devices
should be disconnected from the
mains immediately and taken out of
operation.
The device shall not be opened.
Use the repair service of the manu-
facturer.
Only connect the device to the elec-
tricity networks provided to that pur-
pose.
The safety of the system in which
the device is integrated is the
responsibility of the installer.
Disconnect all electricity networks
prior to any installation or mainte-
nance work.
Use exclusively cables approved in
your country and designed for your
temperature and power ranges.
Installation and service work shall
be carried out exclusively by quali-
fied personnel.
The device must compulsorily be pro-
tected with approved external fuses.
The value of these fuses can be
found in the technical information.
This symbol is used on the device to
!
remind of the existence of dangers,
which are referred to in this manual.

2.1 Use according to the intended purpose

The counter detects and measures pulses, times
and frequencies up to max. 60 kHz and offers a
wide variety of different operating modes. Use for
any purpose over and beyond this will be
deemed as not in accordance with its intended
purpose and thus not complying with the require-
ments.
The application area for this device lies in indus-
trial processes and controls, in the fields of man-
ufacturing lines for the metal, wood, plastics,
paper, glass, textile and other like industries.
Over-voltages at the terminals of the device must
be kept within the limits of Over-voltage Catego-
ry II.
Page 1 | ENG