Do not use any other types of oil as they would
influence the function of the hydraulic cylinder.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil
pump and control valve.
The system is complete when the machine is deliv-
ered, and may not be changed or manipulated.
Regularly check the oil level.
• Too low an oil level damages the oil pump.
• Regularly check the hydraulic connections and
bolts for tightness. Retighten if necessary.
• Before undertaking any maintenance or checking
work, the working area must be cleaned. Keep the
necessary tools within the reach of your hand.
• The intervals mentioned herein are based on nor-
mal conditions of use. An excessive use of the ma-
chine shortens the intervals accordingly.
• Clean the panels, screens and control levers with a
soft cloth. The cloth should be dry or slightly humid
with a neutral cleaning agent. Do not use any sol-
vents like alcohol or benzene as they could dam-
age the surfaces.
• Store oil and grease outside the reach of unauthor-
ized personnel. Strictly follow the instructions on
the bins. Avoid direct contact with the skin. Rinse
well after use.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*:
Splitting wedge, log pusher guides, hydraulic oil
* Not necessarily included in the scope of delivery!
11. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
12. Transport
The ventilation screw (12) must be tightly sealed.
The machine should operate under the following en-
vironmental conditions:
minimum
Temperature
5 C°
Humidity
26 | GB
All manuals and user guides at all-guides.com
maxi-
recom-
mum
mended
40 C°
16 C°
95 %
70 %
The machine may be transported while held in a di-
agonal position. Use the hand grip and pull gently
while the machine stands on its wheels. Fig. 7
13. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power sup-
ply the product can cause the voltage to fluctuate
temporarily.
• The product is intended solely for use at connec-
tion points that
a) do not exceed a maximum permitted supply im-
pedance "Z", or
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish to
operate the product meets one of the two require-
ments, a) or b), named above.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H 07 RN".