Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*:
Splitting wedge, Splitting wedge extension, splitting
wedge guides, hydraulic oil
* Not necessarily included in the scope of delivery!
11. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
12. Transport
Transport by hand, Fig. 10
For transport, the splitting knife (6) must be complete-
ly moved down. Slightly tilt the log splitter with handle
(16) on the splitting column until the machine is in-
clined on the wheels and can be moved.
Transport by crane:
Pull through 2 ropes crosswise under the frame and
lift carefully.
Never lift the machine on the splitting knife!
The machine should operate under the following envi-
ronmental conditions:
minimum maximum
Temperature
5 C°
Humidity
Setting up
Prepare the work place where the machine is to
stand. Create sufficient space in order to allow safe
working without disturbance.
The machine has been designed for working on a
level surface. It must therefore be set up in a stable
position on firm ground.
13. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
All manuals and user guides at all-guides.com
recom-
mended
40 C°
16 C°
95 %
70 %
• The product meets the requirements of EN
61000-3-11 and is subject to special connection
conditions. This means that use of the product
at any freely selectable connection point is not
allowed.
• Given unfavorable conditions in the power sup-
ply the product can cause the voltage to fluctu-
ate temporarily.
• The product is intended solely for use at con-
nection points that
a) do not exceed a maximum permitted supply
impedance "Z", or
b) have a continuous current-carrying capacity
of the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish
to operate the product meets one of the two re-
quirements, a) or b), named above.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H 07 RN".
The printing of the type designation on the connec-
tion cable is mandatory.
Mains fuse protection is 16 A maximum.
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE).
Extension cables must have a minimum cross-section
of 2.5 mm².
GB
27