7. Installation
The given operating and performance features can only be guaranteed with the use of DITEC ac-
cessories and safety devices.
Unless otherwise specified, all measurements are expressed in mm.

7.1 Preliminary checks

Check the stability of the wing (derailing and lateral falls) and the sliding wheels and that the upper
guides do not cause any friction.
The sliding guide must be securely fixed to the ground for the full length within doorway and must
have no irregularities that could hinder the movement of the wing.
The opening and closing stops must be fitted.
If the gate has slits, make sure they are covered to prevent shearing points or install active safety
edges on the columns.
Safety device should be installed at the end of the wing to reduce the collision force.
NB:
•Make sure that the gate can not exit the sliding guides and fall.
•Make sure that the protection system and any manual release function correctly.
7.2 Base plate position
Make a concrete base with the anchor ties and base plate embedded, which must be level and
clean and of the size indicated in the figure.
i
NB: if the concrete base has already been made, base plate can be fixed using M8 plugs
(not supplied).
X+20 [*]
[*] CROSSCRI
[*] CROSSCRN2
X=40
OPENING
Ø80
220
40
min
260
9
90°
M12
low type
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ditec ion6Ditec ion4jDitec ion6j

Table des Matières