Technical Data; Preliminary Checks - entrematic Ditec CROSS30 Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
1.

TECHNICAL DATA

Power supply
Absorption
Motor power
Thrust
Door speed
Max run
Service class
Intermittence
Temperature
Control panel
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
[1]
Radio
[2]
Flashing light
[3]
Key selector
[4]
Geared motor + control panel
[5]
Photocells
[6]
Sensitive edge
[7]
Opening and closing stop
[8]
Connect power supply to an type-approved omnipole
switch with a contact opening gap of no less that 3 mm
(not supplied)
Connection to the grid is made with independent channels
and separated from the connections to the control and
safety devices.
[9]
Geared motor
[11] Housing
[12] Terminal board
[13] Release screw
[14] Pinion module 6
[15] Magnetic limit switch
[16] Base plate
[17] Limit switch bracket
[18] Limit switch of release access door
3.
INSTALLATION
in millimetres (mm).
CROSS30 - IP1777
CROSS30E
400 V~ 50 Hz
2,1 A
550 W
3000 N
0,16 m/s
20 m
3000 kg
5 - HEAVY DUTY
S3 = 100%
-20 °C / +55 °C
IP45
E1T (incorporated)

3.1 Preliminary checks

Check the stability of the wing (derailing and lateral falls) and
the sliding wheels and that the upper guides do not cause any
friction.
The sliding track must be securely anchored to the ground and
fully exposed along its full length.
It must be perfectly smooth so as to avoid jamming of the gate.
Provide opening and closing stops.
If the gate has slits, make sure they are covered to prevent
shearing points.
Safety device should be installed at the end of the wing to reduce
the collision force.
3.2 Base plate position
with the supplied nuts.
-
Lay a concrete foundation with buried anchoring brackets
and the base plate, making sure that it is pefectly level and
(the side to be placed in contact with the ground is marked
on the base plate). If a concrete foundation is already
available, secure the motor by means of appropriate
dowels (not supplied) capable of withstanding a pushing
force of at least 3000 N.
10
CROSS30
400 V~ 50 Hz
2,1 A
550 W
3000 N
0,16 m/s
-
3000 kg
5 - HEAVY DUTY
S3 = 100%
-20 °C / +55 °C
IP45
-
X
20

Publicité

Table des Matières
loading

Table des Matières