Display
DC - Setting of disengagement on stop during closure [mm]
Regulates the distance of the disengagement on the mechanical open-
ing stop.
00 - Disabled
99 - Maximum
NB: not active if
OT - Selection of type of obstacle identification
00 - Overcurrent or gate stopped
01 - Overcurrent
02 - Door stopped
NB: the obstacle identification for "door stopped" is faster but more
sensitive.
CR - Stroke estimate correction [%]
DO NOT USE (diagnostic purposes only)
SM - Selection of operating mode of device connected to terminals 1-6
00 - During the operation, the opening of the safety contact stops the movement
(with disengagement if
01 - During the operation, the opening of the safety contact stops the movement
(with disengagement if
tion is resumed.
02 - During the operation, opening of the safety contact stops the movement (with
disengagement if
operation is performed.
03 - During the closing operation, the opening of the safety contact reverses the
movement. During the opening operation, the safety device is ignored.
04 - During the opening operation, the opening of the safety contact stops the
movement (with disengagement if
the opening operation is resumed. During the closing operation, the safety device
is ignored.
05 - During the closing operation, the opening of the safety contact stops and re-
verses the movement. During the opening operation, the opening of the safety con-
tact stops the movement (with disengagement if
TN - Setting of intervention temperature for the NIO electronic anti-
freeze system and automatic HS ramps [°C]
This value does not refer to the ambient temperature, but to the inter-
nal control panel temperature.
TH - High temperature protection enable.
If ON, the automatic reclosing time is extended when the maximum
switchboard temperature is reached. If the condition persists, all the
controls are disabled.
HS - Automatic ramp adjustment
ON - Enabled
OF - Disabled
When enabled (ON), at low ambient temperatures the start time
up to the maximum value and the acceleration time
the minimum value.
NB: for correct operation, the control panel must be exposed to the same ambi-
ent temperature as the motors.
The intervention temperature can be set with the selection
Description
/
).
/
). When the contact closes again, the opera-
/
). When the contact closes again, an opening
/
39
). When the contact closes again,
/
).
increases
and
diminishes to
.
Selections
available
07
20
EN