Manual release instructions
In the event of a fault or power failure, insert the key and
turn it clockwise and completely open the hatch. Manually
open the gate.
To lock the gate again, close the hatch, turn the key anticlock-
wise and remove the key.
WARNING: the gate lock and release operations
must be performed with the motor idle.
Do not enter within the operating range of the gate.
When the hatch is closed but the key is still
horizontal, the release microswitch is open and all
manoeuvres are prevented.
Technical specifications
Maximum stroke
Maximum gate weight
Gate speed
Thrust
Power supply
Power absorption
Fuse
Power
Intermittence
Lifespan
IP degree of protection
Usage temperature
Product size
Control panel
Motor output
Power supply to accessories
0-1
Radio frequency
Storable radio codes
EN
ION4
12 m
400 kg
0.1 - 0.25 m/s
200N nominal, 600N start-up
230 V~ 50/60Hz
0.5 A
T1 A
115W
80 cycles/day, 30 continuous cycles
From 50,000 to 150,000 cycles, depending on the conditions indicated in
table x.x (see the product lifespan charts)
34
-20°C / +55°C
300 x 260 x 195
LCU48
24V
10A max
24V
0.3 A
433.92 MHz
100 / 200 (see RO → MU → 20/10)
50
ION6
600 kg
0.1 - 0.3 m/s
300N nominal, 800N start-up
T1.6 A