7.5 Operation with virtual encoder
ION4-ION6 gearmotors do not require limit switches because they have a virtual encoder.
Mechanical opening and closing end stops must be installed.
The gate automatically slows when approaching the end stops.
WARNING: when the gate reaches the opening or closing limit stop, it reverses briefly to facilitate
manual release of the gearmotor.
7.6 Installation of optional accessories
7.6.1 Magnetic limit switches
The limit switch kit is used to stop the gate before it reaches the opening and closing
i
mechanical stops.
With a limit switch installed, slowdown is carried out at regulated power to overcome
possible friction.
For the installation of the limit switch kit, refer to the NES100FCM manual.
To position the limit switches, you can use the menu
configurations
The display shows the status of the limit switches:
•
: opening limit switch configured and activated;
•
: closing limit switch configured and activated;
•
(both parts of display active): opening limit switch not configured and activated;
•
(no part of display active): closing limit switch not configured and activated;
•
(central part of display active): no limit switch activated;
7.6.2 Battery kit
For installation of the battery kit, refer to the SBU-BBU20-BBU65 manual.
The battery kit guarantees operation if there is a power cut.
i
For advanced control of battery-powered operation, refer to the
EM menu.
7.6.3 Remote release handle
For installation of the remote release handle, refer to the IONSBM and ASR2 manual.
The kit can be used to remotely release the gearmotor.
i
A microswitch guarantees safety.
When the handle is released, the control panel performs a reset
EN
→
).
→
(visible by activating the additional
12