Display
OB - Adjustment of deceleration distance during closing. [cm]
Indicates the distance from the end of the closure stroke for the
start of the deceleration ramp.
05 - Minimum
99 - Maximum
PO - Adjustment of approach speed during opening [cm/s]
Indicates the speed from the end of the deceleration ramp to the
end of the opening stroke
03 - Minimum
10 - Maximum
NB: gradually increase the approach speed if there is a series of
quick vibrations (chattering) in heavy gates installed with a slight
incline.
PC - Adjustment of approach speed during closing [cm/s]
Indicates the speed from the end of the deceleration ramp to the
end of the closing stroke.
03 - Minimum
10 - Maximum
OO - Obstacle detection limit during opening [cm]
Indicates the distance from the opening stop or after the detection
of the opening limit switch
ment is deactivated.
NB: not active if
OC - Obstacle detection limit during closure [cm]
Indicates the distance from the closure stop or after the detection
of the closure limit switch
deactivated.
NB: not active if
LR - Electric lock release time [s]
If enabled, this indicates the electric lock activation time at the start
of every opening operation with the automation closed.
FF - Function of output +LP-
00 - courtesy light
01 - electric lock
02 - electric lock + release stroke
03 - ON-OFF flashing light
04 - ON-OFF flashing light for LED without oscillator
05 - fixed light (at 230V AC, or LED with internal oscillator)
06 - proportional indicator light for open gate (with signal of battery operation)
07 - fixed indicator light for open gate (automation not closed)
08 - automation closed (for fail-safe electromagnets)
09 - automation open
10 - automation moving (can also be used for electromagnets that need to be powered
throughout the operation)
11 - automation opening
12 - automation closing
13 - maintenance alarm
14 - signal for batteries almost flat
ON - output always active
i
NB: make adjustments gradually and only after performing at least three complete
operations to allow the control panel to be set correctly and detect any friction during