12.2 MAXIMUS MHXT
12.2.1 General
AISI 316L stainless steel construction
Passivated and electropolished external surfaces
Silicone O-ring seals
12.2.2 Mechanical
2 holes 3/4" NPT for cable entry
Window with protection grid
Sunshield
Unit weight: 16.5kg (36lb)
12.2.3 Housing's window
Germanium window
• Usable diameter: 56mm (2.2in)
• Thick: 10mm (0.4in)
• External treatment: antiscratch (Hard Carbon
Coating - DLC), antireflection
• Internal treatment: antireflection
• Spectral range: from 7.5μm up to 14μm
• Medium transmittance (from 7.5μm up to
11.5μm): 87.3%
• Medium transmittance (from 11.5μm up to
14μm): 67.3%
12.2.4 Electrical
Supply voltage/Current consumption/Power:
• 230Vac, 0.34A, 50/60Hz, 80W
• 120Vac, 0.5A, 50/60Hz, 60W
• 24Vac, 2.2A, 50/60Hz, 53W
• 12Vdc, 2.8A, 34W
Heater (Ton 15°C±4°C (59°F±7°F), Toff 22°C±3°C
(72°F±5°F))
12.2.5 Serial communications
Serial interface: 1 RS-485 line, half-duplex
MNVCMHX_2222_EN
12.2.6 Cameras
Compatible cameras:
• Power consumption (assembly, camera and lens):
13W max
• Cameras dimensions/Lenses that can be installed
(WxHxL): 80x82x245mm (3.1x3.2x9.6in) max
• Minimum distance between camera and
housing's window: 10mm (0.4in)
12.2.7 Environment
For indoors and outdoors installation
Operating temperature/Installation temperature:
from -40°C (-40°F) up to +60°C (140°F)
Relative humidity: from 5% up to 95%
12.2.8 Certifications
Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN61000-6-4,
EN61000-3-2, EN61000-3-3, EN50130-4, EN55032
(Class A)
RoHS (CE): EN IEC 63000
Outdoor installation (CE): EN60950-22, IEC60950-22
IP protection degree (EN/IEC60529): IP66, IP67
Vibration test: EN50130-5, EN60068-2-6
Electromagnetic compatibility (North America): FCC
part 15 (Class A)
KC certification (certification only valid for the code:
MHXT1C000B)
12.2.9 Certifications - Explosion-proof
applications
ATEX (EN IEC 60079-0, EN 60079-1, EN 60079-31)
IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)
EAC EX (TR CU 012/2011)
KCs (Employment and labor department 2021-22)
UK Ex (EN IEC 60079-0, EN 60079-1, EN 60079-31)
37