12.1.4 Serial communications
Serial interface: 1 RS-485 line, half-duplex
Addressable units: Up to 31, via dip-switch
Protocols:
• PELCO D: 2400baud, 9600baud
• VIDEOTEC MACRO: 9600baud, 38400baud
PELCO is registered trademark.
The product may be interfaced with devices not manufactured by
VIDEOTEC. It is possible that the interface protocols have changed or
are in a different configuration from earlier tested units by VIDEOTEC.
VIDEOTEC recommends a test prior to installation. VIDEOTEC will
not be liable for any installation costs or lost revenues in the event a
compatibility problem will occur.
12.1.5 I/O
Version with wiper
• Remote wiper activation: 1 input, dry contact NO
• Day/Night camera status: 1 input
• Wash system activation relay: 1 output, 60Vdc
max or 30Vac max, 1A
• Illuminator activation relay: 1 output, 60Vdc max
or 30Vac max, 1A
12.1.6 Cameras
Compatible cameras:
• Power consumption (assembly, camera and lens):
13W max
• Cameras dimensions/Lenses that can be installed
(WxHxL): 80x82x245mm (3.1x3.2x9.6in) max
• Minimum distance between camera and
housing's window: 10mm (0.4in)
36
12.1.7 Environment
For indoors and outdoors installation
Operating temperature/Installation temperature:
from -40°C (-40°F) up to +60°C (140°F)
Relative humidity: from 5% up to 95%
12.1.8 Certifications
Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN61000-6-4,
EN61000-3-2, EN61000-3-3, EN50130-4, EN55032
(Class A)
RoHS (CE): EN IEC 63000
Outdoor installation (CE): EN60950-22, IEC60950-22
IP protection degree (EN/IEC60529): IP66, IP67
Vibration test: EN50130-5, EN60068-2-6
12.1.9 Certifications - Explosion-proof
applications
ATEX (EN IEC 60079-0, EN 60079-1, EN 60079-31)
IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)
EAC EX (TR CU 012/2011)
KCs (Employment and labor department 2021-22)
UK Ex (EN IEC 60079-0, EN 60079-1, EN 60079-31)
MNVCMHX_2222_EN