Check that the jumper is inserted into connector J4.
J4
Fig. 21
Power cables to be used: 1.5mm² (15AWG).
• Earth wire type TEWN with cross section equal or
bigger than line and neutral cable.
• Line and neutral wire type TFFN or MTW
6.8.2 Connection of the power supply
line in 120Vac and 230Vac for MHX
without wiper
Insert cables into the product for a
sufficient length to facilitate wiring.
Slide the power cables through the entry device.
Pull out the removable terminal (J9, connectors
board).
Earth cable should be about 10mm longer
than the other two, so that it will not be
disconnected accidentally if pulled.
The power supply cable must be covered
by the silicone sheath (01) supplied. The
silicone sheath must be fastened with the
corresponding cable tie (02).
22
L/+
N/-
Fig. 22
Reinsert the wired terminal in the connector.
J9
Fig. 23
CONNECTING THE POWER SUPPLY
Cable colour
Power supply 230Vac
Blue
Brown
Yellow/Green
Power supply 120Vac
Blue
Brown
Yellow/Green
Tab. 8
Power cables to be used: 1.5mm² (15AWG).
• Earth wire type TEWN with cross section equal or
bigger than line and neutral cable.
• Line and neutral wire type TFFN or MTW
01
02
Terminals
(N) Neutral
(L) Phase
Earth
(N) Neutral
(L) Phase
Earth