6.8.3 Connection of the power supply
line in 24Vac, 120Vac, 230Vac and 12Vdc
for MHX with wiper and for MHXT
Insert cables into the product for a
sufficient length to facilitate wiring.
Slide the power cables through the entry device.
Pull out the removable terminal (J9, connectors
board).
Earth cable should be about 10mm longer
than the other two, so that it will not be
disconnected accidentally if pulled.
The power supply cable must be covered
by the silicone sheath (01) supplied. The
silicone sheath must be fastened with the
corresponding cable tie (02).
N/-
L/+
Fig. 24
Reinsert the wired terminal in the connector.
Fig. 25
Power cables to be used: 1.5mm² (15AWG).
• Earth wire type TEWN with cross section equal or
bigger than line and neutral cable.
• Line and neutral wire type TFFN or MTW
MNVCMHX_2222_EN
01
02
J9
6.9 How to install the camera/
lens
Compatible cameras (4.5 Characteristics of
installable devices, page 11):
• Power consumption (assembly, camera and lens):
13W max
• Cameras dimensions/Lenses that can be installed
(WxHxL): 80x82x245mm (3.1x3.2x9.6in) max
• Minimum distance between camera and housing's
window: 10mm (0.4in)
Install the camera/lens on the internal slide using
the screws and the spacers supplied, so that the
installation height allows perfect vision through the
window.
Fig. 26
The minimum installation distance between the
camera and the window is 10mm (0.4in). To observe
this constraint the camera mount limit is 5mm (0.2in)
from the front edge of the inner slide.
Enclosure
glass
window
Internal
slide
Camera
Fig. 27
23