6.5 Housing opening
Before carrying out any type of
intervention, read the "Safety rules"
chapter of this manual.
To install the camera open the rear flange of the
enclosure.
Remove the M6 screws on the rear cover plate of the
housing (rear flange).
After removing the screws, the rear flange will
remain in place due to the presence of the O-ring.
To facilitate removal of the rear flange and avoid
damaging the O-ring, use the 3 x M5x60mm
hexagonal head extraction screws supplied.. Once
the extraction screws have been inserted, act on
them symmetrically (2 or 3 turns at a time per screw)
in order to slowly extract the flange.
During opening and closure operations of
the product, pay attention not to damage
the flameproof joint.
Fig. 11
18
Screws properties:
• Diameter/Screw pitch: M6x0.8
• Material: A2 or A4 Class 70
• Screw head: ISO 4762
• Length: 18mm
• Yield stress: 450N/mm²
Disconnect J3 and J8 connectors (version
with wiper).
Fig. 12
J3
J8
MNVCMHX_2222_EN