8
FURTHER INFORMATION
The following accessories are envisaged for WALKY (radio receiver): the Oview
programmer, the Solemyo solar power system and the back-up battery mod.
PS424.
8.1 - Connection of the OXI radio receiver
To connect the OXI receiver, first cut off the electricity supply to the control unit
and proceed as illustrated in fig. 27. Table 12 and Table 13 indicate the com-
mands which correspond to the outputs on the control unit.
SMXI / SMXIS or OXI / OXIFM / OXIT / OXITFM in mode I or Mode II
Output 1
Command "P.P." (Step-Step)
Output 2
Command "Partial opening 1"
Output 3
Command "Opens"
Output 4
Command "Closes"
OXI / OXIFM /OXIT / OXITFM in mode II extended
No.
Command
Description
1
Step-Step
Command "P.P." (Step-Step)
2
Partial opening 1
Command "partial opening 1"
3
Opens
Command "Opens"
4
Closes
Command "Closes"
5
Stop
Stop the manoeuvre
6
Step-Step
Command in Apartment Building mode
Apartment Building
7
Step-Step
Command even with automation system secured or com-
high priority
mands activated
8
Partial opening 2
Partial opening (opening of leaf M2 to half of its total travel)
9
Partial opening 3
Partial opening (opening of both leaves to half of their total
travel)
10
Opens and Secure
Causes an opening manoeuvre at the end of which the
automation system
automation system is secured; the control unit does not
accept any other command except for the "Step-Step
high priority", "Release" automation system or (only from
Oview) the commands: "Release and close" and "Release
and open"
11
Closes and Secure
Causes a closing manoeuvre at the end of which the
automation system
automation system is secured; the control unit does not
accept any other command except for the "Step-Step
high priority", "Release" automation system or (only from
Oview) the commands: "Release and close" and "Release
and open"
12
Secure automation
Causes the manoeuvre to be stopped and the automation
system
system to be secured; the control unit does not accept
any other command except for the "Step-Step high priori-
ty", "Release2 automation system or (only from Oview) the
commands: "Release and close" and "Release and open".
13
Release automation
Causes the automation system to be released and normal
system
operation to be restored
14
On Timer Courtesy
The Courtesy light output is turned on with timed switch-
Light
off
15
On-Off Courtesy
The Courtesy light output is turned on and off in On-Off
Light
mode
8.2 - Connection and installation of the back-up battery
mod. PS424
IMPORTANT! - The battery must only be connected to the control unit
after all the phases of installation and programming have been complet-
ed, as the battery constitutes a source of emergency power.
To arrange connection to the Solemyo system, follow the stages of assembly
fig. 28.
8.3 - Connection of the Oview programmer
The control unit has a BusT4 connector to which the Oview programming unit
can be connect, and which allows the complete rapid management of the
installation and maintenance phase as well as the diagnosis of the entire
automation system. To access this connector, proceed as shown in fig. 29 and
connect the connector to the dedicated seat. The Oview can be connected to
several Control units simultaneously (up to 5 without any particular precautions,
and up to 60 observing the dedicated warnings) and can stay connected to the
control unit even during the normal operation of the automation system. In this
case, it can be used to send the commands directly tot he control unit using the
specific "user" menu. The Firmware upgrade can also be carried out. If there is
a radio receiver from the OXI family in the control unit, Oview can be used to
gain access to the parameters of the transmitters stored in the receiver itself.
10 – English
TABLE 12
TABLE 13
For further information, please consult the relevant instruction manual and the
manual for the "Opera system book" system.
8.4 - Connection of the Solemyo solar power system
IMPORTANT! – When the automation system is powered by the "Sole-
myo" system, IT MUST NOT BE POWERED concurrently by the electricity
mains.
For further information about the Solemyo system, please refer to its instruction
manual.
To arrange connection to the Solemyo system, follow the stages of assembly
illustrated in fig. 30.
To complete the connection between Solemyo and the gearmotor control unit,
use the dedicated adapter cable.
9
PRODUCT MAINTENANCE
In order to keep the safety level constant and to guarantee the maximum life
span of the entire automation system, regular maintenance is vital.
All maintenance work must be carried out in compliance with the safety provi-
sions of this manual and in accordance with existing laws and regulations.
The product requires frequent inspection to check for imbalances of the doors
or signs of wear or damage to the cables. Do not use the product if adjust-
ments or repairs are required.
Important – During the product maintenance or cleaning operations, cut
off the electricity supply to the control unit and any batteries envisaged.
For the other devices in the system, follow the instructions provided in their
respective maintenance schedules.
For gearmotors WL1024C, WL1024, scheduled maintenance is required at the
latest 6 months or 20,000 manoeuvres after the previous maintenance work.
Maintenance can be performed as follows:
01. Cut off any electrical power source, including any back-up batteries;
02. Check the condition and wear of brackets and fixing plugs, paying special
attention to erosion or rusting; replace all parts which do not provide suffi-
cient guarantees;
03. Perform a trial release to ensure it is working properly – see paragraph 3.8.
04. Reconnect the electrical power sources and perform all the checks envis-
aged in chapter 5.1 - Testing.