6.2 - Level two programming (adjustable parameters)
All level two parameters are programmed at the factory as highlighted in grey in
Table 8 and can be modified at any time following the procedure described in
Table 7.
The parameters are adjustable on a scale of values from 1 to 4; to check the
value corresponding to each LED, please see Table 8. IMPORTANT – The pro-
01. Press and keep key "Set" pressed for approximately 3 seconds;
02. Release the key when LED "L1" begins to flash;
03. Press key " " or " " to move the flashing LED to the LED representing the "input LED" of the parameter you wish to change;
04. Press and keep pressed the "Set" key until step 06 is complete;
05. Wait approximately 3 seconds until the LED representing the current level of the parameter to be changed is turned on;
06. Press key " " or " " to move the LED representing the value of the parameter;
07. Release the "Set" key;
08. Wait 10 seconds (maximum) to exit programming mode.
Note – To program several parameters when the procedure is in progress, repeat steps 03 to 07 during the phase itself.
input LED
Parameter
LED
(level)
L1
Pause
L1
Time
L2
L3
L4
L2
Step-Step
L1
Function
L2
L3
L4
L3
Motor
L1
velocity
L2
L3
L4
L4
Motor
L1
force
L2
L3
L4
6.3 - Memory deletion
To delete the memory of the control unit and restore all the factory settings, pro-
ceed as follows: press and keep pressed keys " " and " " until LEDs L1 and
L2 start to flash.
6.4 - Special functions
Function: "Move anyway"
This function makes it possible to operate the automation system even when a
safety device is not working properly or is out of order.
The automation system can be controlled in "push to run" mode as follows:
01. Send a command to operate the gate, using a transmitter or key selector,
etc. If everything is working properly, the gate will move normally, otherwise
proceed as follows:
02. Within 3 seconds, send the command again and keep it activated;
03. After approximately 2 seconds, the gate will perform the manoeuvre
8 – English
TABLE 7 - Level two programming procedure
TABLE 8 - Level two functions
Value
5 seconds
30 seconds
60 seconds
120 seconds
Opens – stop – closes – stop
Opens – stop – closes – opens
Opens – closes – opens – closes
Apartment building:
• during the opening manoeuvre, the "Step-Step" and "Opens" commands
do not have any effect; on the other hand, the "Closes" command causes
the movement to be inverted, i.e. the leaves to close.
• during the closing manoeuvre, the "Step-Step" and "Opens" commands
cause the movement to be inverted, i.e. the leaves to open; on the other
hand, the "Closes" command does not have any effect.
Slow
Medium
Fast
Very fast
Level 1 - Minimum force
Level 2 - ...
Level 3 - ...
Level 4 - Maximum force
gramming procedure has a maximum time of 10 seconds between one key and
another being pressed. After this time, the procedure ends automatically, stor-
ing the changes made up until that moment.
requested in "push to run" mode; i.e. the gate will continue to move only
for as long as the command is activated.
When the safety devices do not work, the flashing light emits a few flashes to
indicate the type of problem (see chapter 7 - Table 10).
3 s
L1
or
or
10 s
Description
Adjusts the pause time, i.e. the amo -
unt of time before the gate closes au -
tomatically. Only effective is Close is
activated.
Adjusts the sequence of commands
associated with the "Step-Step" in -
put or radio command.
Note – When L4 is set, the behaviour
of the "Opens" and "Closes" comma -
n ds is also modified.
Adjusts the velocity of the motors du -
ring normal travel.
Adjusts the force of both motors.