Télécharger Imprimer la page

Nice WALKY WL1024 Instructions Et Avertissements Pour L'installation Et L'utilisation page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
DISPOSING OF THE PRODUCT
This product is an integral part of the automation system, and should
therefore be disposed of together with it.
As for the installation operations, even at the end of this product's life span, the
dismantling operations must be carried out by qualified experts.
This product is made up of various types of materials: some can be recycled
while others need to be disposed of. Find out about the recycling or disposal
systems envisaged by your local regulations for this product category.
Important! – Parts of the product could contain pollutants or hazardous sub-
stances which, if released into the environment, could cause harmful effects to
the environment itself as well as to human health.
As indicated by the symbol opposite, throwing away this
product as domestic waste is strictly forbidden. So dispose
of it as differentiated waste, in accordance with your local
regulations, or return the product to the retailer when you
purchase a new equivalent product.
WARNINGS: • All technical specifications are referred to a room temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to make any changes deemed nec-
essary to the product at any time while maintaining the same functions and intended use.
Type: Electric gearmotor for automated gates and doors with direct reduction gear and mechanical release mechanism. Only for model WL1024C: built-in con-
trol unit and OXI radio receiver
Maximum torque: 100 Nm
Nominal torque: 50 Nm
Idle velocity: 0.20 rad/s - 0.3 rad/s
Velocity at nominal torque: 0.16 rad/s - 0.24 rad/s
Maximum cycle frequency: 100 complete cycles per day (the control unit of WL1024C limits to a maximum of approximately 50 cycles/hour)
Maximum continuous cycle time: approx. 10 minutes
Usage limitation: the product can be used on gates weighing up to 180 kg (0.8 m leaf) pr with a leaf length of up to 1.8 m and an angle of aperture of up to 110°
Power supply: WL1024C: 230 VAC (+10% -15%) 50/60 Hz; WL1024: 24 VDC (50%); WL1024C/V1: 120 VAC (+10% -15%) 50/60 Hz
Emergency power supply: Designed to accommodate back-up battery PS424
Solar panel power supply: designed to accommodate SOLEMYO kit
Nominal absorbed power from electricity mains (WL1024C): 120 W
Nominal absorbed current (WL1024): 2 A; at pick-up the current is 3 A for a maximum time of 2 s
Power absorbed from the electricity mains with "Standby – All (1)" function activated (including the OXI receiver): 3 W
Power absorbed when operating on back-up battery or SOLEMYO KIT with "Standby-All (1)" function activated (including the OXI receiver): less than
100 mW (including the OXI receiver)
Electrical lock output [*]: a 12 VAC max 15 VA electrical lock
Flashing output [*]: a flashing WLT or a 12VDC lamp, 21 W max
BLUEBUS output: an output with maximum load of 15 Bluebus units (maximum 6 pairs of MOFB or MOFOB photocells plus 2 pairs of MOFB or MOFOB pho-
tocells addressed as opening devices plus maximum 4 MOMB or MOTB control devices)
STOP input: for normally closed, normally open contacts or with a constant resistance of 8.2 kΩ; the selection of the type of contact takes place in auto-recog-
nition and a variation compared to the status stored causes the "STOP" command
PP input: for normally open contacts (the closing of the contact causes the Step-Step command)
Radio connector: SM connector for receivers from the SMXI, OXI and OXIFM families
Radio AERIAL input: 50 Ω for type RG58 or similar cable
Programmable functions: 4 ON-OFF type functions (Table 5) and 4 adjustable functions (Table 8)
Functions in auto-recognition: • Auto-recognition of the devices connected to the BlueBus output. • Auto-recognition of the type of device connected to the
"STOP" terminal (NO, NC or 8.2 kΩ resistance contact). • Auto-recognition of the travel of the leaves and automatic calculation of the points of deceleration and
partial opening. • Auto-recognition of operation with one or two motors
Assembly: Vertically, with a dedicated fastening plate
Operating temperature: from -20°C to +50°C (at low temperatures the efficiency of the gearmotor decreases)
Usage in particularly acidic or saline or potentially explosive atmosphere: NO
Protection rating: IP 44 (with casing intact)
Dimensions (mm): 90 x 125 x 385 h
Weight (kg): (WL1024C) 4.8; (WL1024) 4.3
Note:
––––––––––
(1) - Function which can be activated with the Oview programmer.
[*] - The outputs of the terminals on the control unit ("Electrical lock") and on the power unit ("Flash") can be reprogrammed with other functions, using the Oview programmer. The elec-
trical characteristics of these two outputs are adapted depending ont he type of function chosen:
• "electrical lock" function: 12VAC, 15VA max;
• "flashing" function: a WLT multi-purpose lamp, or a 12VDC lamp, 21W max;
• other types of functions: a lamp or a relay at 24VDC (-30% and +30%), 4 W max, if the control unit is mains powered, or a lamp or relay at 12VDC (-10% and +25%), 4 W max, if the
control unit is powered by the back-up battery PS424.
Important! – the local applicable regulations may envisage heavy sanctions in
the event of illegal disposal of this product.
Disposal of the back-up battery (where present)
Important! – The flat battery contains pollutants and should therefore not be
thrown away as common waste.
It should be disposed of as differentiated waste, as envisaged by your local
applicable regulations.
PRODUCT TECHNICAL SPECIFICATIONS
English – 11

Publicité

loading

Ce manuel est également adapté pour:

Walky wl1024c