Série Endurance®
Manuel d'utilisation, Rev. 2.1, Feb 2022
Description
Error Codes
Emissivity source
Valley hold time (1)
Average time (1)
Gateway Address
Top temperature range for mA
output
RS485 mode
Sensor internal ambient
Analog input mA, current
value
Analog input mode
IP Address
Switch panel lock
Relay alarm output control
Bottom temperature range for
mA output
Color mode
MAC Hardware Address
Target temp:1C narrow
Net Mask
Output current
Output format
Analog output gain
Analog output offset
148
Char
Value Format
Poll Burst Set Legal Values
nnnnnnnnnnnnnnnn √
EC
ES
X
F
n.n - nnn.n
G
n.n - nnn.n
GW
nnn.nnn.nnn.nnn
nnnn.n – nnnn.n
H
HM
n
I
n.n - nnn.n
nn.nn – nn.nn
IN
INM
n
IP
nnn.nnn.nnn.nnn
J
X
K
n
n.n – nnnn.n
L
M
n
MAC
nnnnnnnnnnnn
N
n.n - nnnn.n
NM
nnn.nnn.nnn.nnn
O
nn
OIF
OUG
n.nn
OUO
-nnn - +nnn
15
2
alarm detection
14
2
narrow band temp. over
range
13
2
narrow band temp. under
range
12
2
wide band temp. over range
11
2
wide band temp. under
range
10
2
two-color temp. over range
9
2
two-color temp. under range
8
2
attenuation>95% (dirty
window)
7
2
attenuation too high (> 95%)
6
2
energy too low
5
2
narrow band detector failure
4
2
wide band detector failure
3
2
internal temp. under range
2
2
internal temp. over range
1
2
heater control temp. under
range
0
2
heater control temp. over
range
I = set by a constant number
according to the command "E"
E = set by the analog input
0.0 – 300.0 s (300 s = )
0.0 – 300.0 s (300 s = )
0.0.0.0 - 255.255.255.255
min/max of temperature range
(°C or °F)
2 = 2 wire
4 = 4 wire (for Endurance glass
fiber models only)
0°C/32°F – 65°C/149°F
0 - 20 or 4 - 20
0 = 0 – 20 mA
4 = 4 – 20 mA
0.0.0.1 - 255.255.255.255
L = Locked
U = Unlocked
0 = Permanently Open
1 = Permanently Closed
2 = Normally Open
3 = Normally Closed
4 = Normally Open
5 = Normally Closed
0.0 – 9999.0 (°C or °F)
1 = 1 - color
2 = 2 - color
e.g. 001d8d2aaa01
0.0.0.1 - 255.255.255.255
00 = controlled by unit
02 = under range
21 = over range
0 – 20 = current in mA
0 = temperature value format is
float with one decimal place
1 = temperature value format is
integer with four digits
0.01 to 100.0
-200 to +200
Factory Default
I
000.0
000.0
192.168.42.1
High temperature
range of sensor
2
0
192.168.42.132
Unlocked
2
for a detailed
description, see
section 11.6.2
Sortie
relais, page 81
Low temperature
range of sensor
2
Set at factory
calibration
255.255.255.0
00
0
1.0
0.0