3.
Setup
Use this procedure to set up the spray system.
1. Make sure the diaphragm pump ON/OFF switch and the
compressor ON/OFF switch are in the OFF position.
2. Make sure the pressure control knob is turned fully
counterclockwise to its lowest pressure setting.
3. Using a wrench, attach a minimum of 7.5 m of 6 mm nylon
airless spray hose to the material outlet fitting on the pump.
Tighten securely.
4. Attach the air hose to the air outlet fitting on the compressor.
Tighten securely.
5. Lock the gun by flipping the trigger lock into lock position (see
spray gun manual).
Make sure to read the spray gun's instruction
manual in order to be familiar with all of its functions
and corresponding safety information.
6. Attach the spray hose to the material inlet fitting on the spray
gun. Using two wrenches (one on the gun and one on the
hose), tighten securely.
1
2
Finish 230 AC Compact
GB
7. Attach the air hose coupling to the air inlet fitting on the spray
8. Make sure the electrical service is 230V, 10 amp minimum.
9. Plug the power cord into a properly grounded outlet at least
5
7
6
21
Make sure all airless hoses and spray guns are
electrically grounded and rated for at least 193 bar
(19 MPa, 2800 PSI) fluid pressure.
gun. Attach the air hose to the coupling. Tighten securely.
Reversing the hose connections could result in
serious injury. Make sure the airless spray hose is
connected from the diaphragm pump to the material
inlet fitting on the gun and the air hose is connected
from the compressor to the air inlet fitting on the
gun.
7.5 m from the spray area.
3
Setup
4