Installation and operating manual
If the load limiting device does not react:
–
Remove the blanking plug (1).
–
Loosen the brass screw (2).
–
Insert an 8 mm, 150 mm-long Allen key into the setting screw (3).
–
Loosen the setting screw (3) until the load limiting device reacts.
–
Lower the overload to the ground.
–
Raise the overload again.
The load limiting device must react. Otherwise repeat the procedure.
The load limiting device must not react when the hoist is loaded to the working load limit.
–
Load the load lifting equipment with the maximum working load.
–
Raise until the load lifting equipment hangs freely.
The load limiting device must not react when lifting the load.
If the load limiting device reacts:
–
Lower the load to the ground.
–
Insert an 8 mm, 150 mm-long Allen key into the setting screw (3).
–
Tighten the setting screw (3) one half turn.
–
Raise the load again.
The load limiting device must not react when lifting the load.
If setting screw (3) was adjusted, repeat the test with the maximum overload.
–
Load the load lifting equipment with the calculated overload.
–
Raise the load.
The load limiting device must react and stop the UP travel of the hoist within the first 10 cm.
–
Tighten the brass screw (2).
–
Replace the blanking plugs (1) and secure with red sealing wax.
Type series X 2050 P
Illustration 30
–
Load the load lifting equipment with the calculated overload.
–
Raise the load.
The load limiting device must react and stop the UP travel of the hoist within the first 10 cm.
If the load limiting device does not react:
–
Remove the blanking plug (1).
–
Insert a screwdriver into the setting screw (3).
–
Loosen the lock nut (5) with the socket wrench.
–
Screw in the setting screw (3) until the load limiting device reacts.
EN-54
G1035.4 – 01/2019