Changing The Internal Deburrer Blade; Changing The Pipe Cutter Cutting Wheel; Changing The Clamping Jaw Inserts (H); Daily Inspection - Rothenberger SUPERTRONIC 2 SE Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
6.1

Changing the internal deburrer blade

Always wear protective gloves when replacing the blades! Risk of cuts and
injury!
Î Remove the spring pin out of the next of the reamer blade.
Î The reamer blade is released when you pull the reamer blade holder forwards.
Î Fit a new reamer blade.
Î Put the previously removed spring pin back into the hole of the new reamer blade.
6.2

Changing the pipe cutter cutting wheel

Always wear protective gloves when replacing the blades! Risk of cuts and
injury!
Î Bring the pipe cutter into an upright position and lower the thread-tapping head.
Î Pull off the cotter pin upwards.
Î Hold the cutting wheel and push the cutting wheel straight pin slowly out on the opposite
side.
Î Insert a new cutting wheel into the blade holder and insert the pin again.
Î Insert a new cotter pin into the cutting wheel straight pin and secure it by bending it apart.
6.3
Changing the clamping jaw inserts
Î
Turn the clamping chuck and open it until a screwdriver (2 SE)
or an Allan key (3 SE) fits inside.
Î
Undo the screws that secure the clamping jaw inserts (fig. 1).
Î
Place a thin rod onto the upper edge of the spring and pull out
the clamping chuck pin (fig. 2).
Î
Pull the clamping jaw insert forward (fig. 3).
Î
Insert a new clamping jaw insert and push it right to the back,
replace the spring and the clamping chuck pin. Tighten the
screw.
6.4

Daily inspection

Attention! Before starting the lubrication-works the power plug has to be
taken out of the power source.
Î Check the mains plug, mains cable and extension cable to ensure they are undamaged.
Î Correctly filled oil trough.
Î Clean the oil tank if there are impurities in it.
Î Inspect the dies, pipe cutter and internal deburrer for any wear and replace parts if there is
wear.
Î Clean the clamping jaws with a wire brush if they are dirty.
Î Check that the dowel screws are secure. Tighten if necessary.
Î Remove dirt and chips from the machine regularly.
Î Apply anti-rust grease if the machine is not going to be used for an extended period.