WALL-MOUNTED INSTALLATION—VENTED TO THE OUTSIDE
6
CONNECT DUCTWORK
■ I nstall ductwork, making connections in direction of
airflow as illustrated.
■ P ush duct over the exhaust outlet and damper.
■ S ecure joints in ductwork with sheetmetal screws.
■ W rap all duct joints with duct tape for an airtight
seal.
■ U se duct tape to seal the flange connections.
Duct tape
over seam
and screw
CAUTION
Do not use sheet metal screws at
the hood flange connection. Doing so will prevent
proper damper operations. Seal connection with tape
only.
12
Installation Instructions
Air flow
Screw
7
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
a ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.
■ R emove junction box cover and knockout.
■ U se a conduit connector to secure the conduit to
the junction box.
■ C onnect white leads to branch circuit white lead.
■ C onnect black leads to branch circuit black lead.
■ C onnect green/yellow leads to branch circuit green
lead or bare ground lead.
■ S ecure all connections with wire nuts on each
electrical connector.
■ P ush wires into junction box and replace cover.
Be sure wires are not pinched.
■ S ecure electrical panel cover with original screws.
1" = 2.5 cm; 1' = 0.3 m