7.
AUTO SCAN – SAVE AND EXIT
To save the memorized data and escape this page, move joystick to the right direction
when cursor is at SAVE AND EXIT.
8.
AUTO SCAN – EXIT
To escape this page without saving, move joystick rightwards here.
F. TOUR SET
8 programmable tours can be set and each tour is capable to memorize up to 60 preset steps.
After setting the data to each tour group, 71~78 + PRESET or 1~8 + PATTERN buttons are
working as group tour # 1~8.
Maxpro protocol provides only three quick operation keys (87~89 + preset) for group
tour, but it is possible to set up to group tours #8.

TOUR SET

TOUR NO
TOUR TITLE
TOUR STEP
PRESET NO.
DWELL TIME
SPEED
SAVE
EXIT
1.
TOUR SET – TOUR NO.
Up to 8 group tours are available to set by the joystick.
2.
TOUR SET – TOUR TITLE
To set tour title, select up to 16 characters moving Joystick to the left or right.
Press ZOOM TELE button to move to the next character from the left to the right and
ZOOM WIDE button to move to the prior character from right to left.
Space is displayed when" " appears. The Tour title is not displayed on the monitor, it is
only for the reference of menu controller.
3.
TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset positions for sequential images with different
dwell time and speed. It is possibly to match any preset # for each tour step.
4.
TOUR SET – PRESET NO.
Connect with tour step #1 ~60; it is possible to select any preset no. from 1 to 64 and
100 to 200. The default setting is BLK for blank, which means tour step is not assigned
to any preset number.
5.
TOUR SET – DWELL TIME
Each Tour step has its own dwell time from 01 second up to 99 seconds.
The default setting is 03 seconds.
: 01
: TOUR01□□□□□□□□
: 01
: 01
: 03
: 300°/S
60
DEFAULT SETTING