Avoid putting the connection cables of buttons, security devices and inputs close to those of the power supply of the control unit and of the motor. Some
parts of the control unit are subject to dangerous voltage. The control unit must be installed and programmed only by qualified professionals. Always use
a device that ensures the disconnection of all poles of the control unit's power supply .
This device can be a switch (connected directly to the power supply terminals) with a contact's minimum distance of 3 mm for each pole, or it can be a
device connected to the power network;
For connecting the card and the motors we recommend to use cables with double isolation as imposed by the laws in force; the minimum cross section
of the single conductor must not be less than 1mm² and not more than 2.5mm².
The presence of a dampness or metal parts in the walls nearby may negatively influence the capacity the system; it is therefore important to carefully
put the aerial and the transmitters away from walls and/or metal structures, away from the ground and not on the ground.
A tuned aerial is needed to maximize the performances in terms of the range; the range would only be a few meters without it.
If the cable supplied is too short, then do not join an extension to it , but replace the whole cable with one of the right length whose impedance is 50
Ohm (RG 58 type). The cable should never be longer than 10 meters. This control unit has a photocells test circuit.
Power voltage (terminals n.1, 2)
Absorption
Photocells power supply (terminals 21, 22, 23)
Photocells' transmitters power supply (terminals 21,22)
Photocells' receivers power supply (terminals n.22, 23)
Motor output (terminals n.5, 6, 7)
Flashing light exit (terminals n.8, 9)
Courtesy light exit (terminals n.3, 4)
Electrical lock (only with R1 card). Clean contact output
NOT supplied with power
Functioning temperature
Courtesy light time
Frequency
Available reception
Maximum range (with tuned aerial and under optimal
conditions)
Aerial impedance
Number of codes available
Recordable transmitters
DISPOSAL OF THE PRODUCT - This product is an integral part of the automation, and therefore, they must be disposed of together. As for the instal-
lation operations, at the end of the life of this product, the dismantling operations must be performed by qualified personnel. This product is made from
different types of materials: some can be recycled, others must be disposed of. Please inform yourselves on the recycling or disposal systems provi-
ded for by the laws in force in your area, for this category of product.
CAUTION! – some parts of the product can contain polluting or dangerous substances which, if dispersed in the environment, may
cause serious harm to the environment and human health.
As indicated by the symbol at the side, it is forbidden to throw this product into domestic refuse. Therefore, follow the "separated
collection" instructions for disposal, according to the methods provided for by local regulations in force, or redeliver the product to
the retailer at the moment of purchase of a new, equivalent product.
CAUTION! – the regulations in force at local level may envisage heavy sanctions in case of abusive disposal of this product.
GUARANTEE - In compliance with legislation, the manufacturer's guarantee is valid from the date stamped on the product and is restricted to the re-
pair or free replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The
guarantee does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect
product, assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired.
Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused by environ-
mental interference. The manufacturer's responsibility for damage caused to persons resulting from accidents of any nature caused by our defective
products, are only those responsibilities that come under Italian law.
6-1622158 REV.03
25/09/2020
WARNING AND ADVICES
ERMES2 Technical features
230 Vac +15%, -15% ; 50Hz
5W MAX (except for accessory and utilities)
24 Vac 3 MAX
24Vac 1,5W MAX
24Vac 1,5W MAX
230Vac 600W MAX cosj > 0.8
230 Vac 60W MAX (for fixilight without blinking circuit)
230Vac 100W MAX
24 Vac 0.5A MAX (12W MAX)
-10°C ... +60°C
1 minute
433.92 MHz
Super-reactive broad band (ERMES2 433);
Super-reactive narrow band (ERMES2 433/S)
Fix code
Rolling code
40 - 60 m (433)
60–100 m (433/S)
50 Ω (tuned aerial)
4096 (FIXED CODE reception)
18 billion of billions (ROLLING CODE reception)
1000 with B.RO 1000 memory module (ROLLING CODE)