Télécharger Imprimer la page

Allmatic B1EE ERMES2 Guide D'installation page 19

Publicité

Les langues disponibles

Les langues disponibles

COM.
5
S.S.
COM.
6
PHOTO.
COM.
7
STOP
COM.
8
EDGE
COM.
L.S.CL.
9
L.S.OP.
COM.
10
PED.
SIGN.
GND
11
+Vdc
12
13
25
24
6-1622158 REV.03
25/09/2020
Connect the STEP BY STEP button (SS)
10
between clamps 10 and 11 of the terminal
board. ATTENTION: leave it open if it is
11
not used.
Connect the NORMALLY CLOSED contact
10
of the photocells (FOTO) between clamps 10
and 12 of the terminal board.
ATTENTION: Jumper input 10 to input 12 if it
is not used.
12
Connect the NORMALLY CLOSED STOP
10
contact between clamps 10 and 13 of the
terminal board
ATTENTION: Jumper input 10 to input 13 if it
13
is not used.
Connect the NORMALLY CLOSED FIX
10
EDGE(C.F) contact between clamps 10 and
14 of the terminal board
ATTENTION: Jumper input 10 to input 14 if it
14
is not used.
Connect the NORMALLY CLOSED closing
limit switch (FC. A) between clamps 10 and
15 of the terminal board.
10
Connect the NORMALLY CLOSED opening
limit switch (FC. C) between clamps 10 and
15
16 of the terminal board.
ATTENTION: Jumper inputs 15 and 16 to
16
input 10 if they are not used.
Connect the PEDESTRIAN (PED.) button
10
between clamps 10 and 17 of the terminal
board. Leave it open if it is not used
17
Connect the encoder's SIGN cable to clamp 18
of the terminal board.
Connect the encoder's GND cable to clamp 19
18
of the terminal board.
19
Connect the encoder's +Vdc cable to clamp 20
of the terminal board.
20
ATTENTION: leave it open if it is not used.
Connect clamp 21 of the control unit
to the first clamp of power supply for
the photocells transmitter.
Connect clamp 22 of the control unit
21
to the second clamp of power
22
supply for the photocells' receiver
and transmitters .
23
Connect clamp 23 of the control unit
to the first clamp of power supply for
the photocells receiver
Connect the aerial's signal cable to
clamp 24 of the terminal board
Connect the aerial's earth to clamp
25 of the control unit
ITA
ENG
The functioning of the STEP BY STEP input (S.S.)
can be open-stop-close-stop (dip1 on OFF) or Open
-close (dip1 on ON). See 8.1. For time functions
see 10.4.
The PHOTOCELLS (FOTO) input can work as a
STOP automatism until the obstacle is removed, for
then restart opening (dip4 on OFF) or causing the
complete opening if the automatism is closing (dip4
on ON). See 8.4
If the STOP input is opened, then this causes an
immediate STOP of the automatism until the
contact is closed. Once closed, the automation
starts to work regularly again.
The activation of the fix edge during the closing or
opening phases causes a short inversion of the
automatism for approximately 2 seconds and then a
stop
The wiring of the limit switches must corresponds to
the
programming the strokes. Follow the procedures of
the preliminary checks for doing that.
The PEDESTRIAN (PED.) opening allows to
partially open the automation.
See chapter 9
The enabling/disabling of the encoder's functionality
is managed by DIP10.
See chapter 8.10
WARNING: The control unit supplies a voltage of
24 Vac and can supply a maximum power of 3 W
The presence of metal parts or humidity into the
walls can influence negatively the range of the sys-
tem; therefore we recommend to avoid to put the
receiver and/or transmitters aerials next to big metal
objects, next to or on the floor.
FRA
ESP
DEU
POR
manual
installation;
check
this
before
3 / 16

Publicité

loading