8.6 Condominium function:
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
8.7 Limit switches operation mode:
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
8.8 Reception type selection:
The control unit was realized for the combined use of two types of transmitters: the fix code ones and the rolling code ones of the Birol® series.
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
NOTE: You must RESET the memory (see paragraph 10.2) every time that a different codifying is selected. If the LEARN led blinks as soon as the
power is given to the control unit, then it means that no memory was entered or the memory and the dip 8 position (reception type selection) do not
correspond. It is not possible to memorize into the same memory both transmitters with fix code and transmitters with rolling code. We remind to
cut the power supply before connecting or disconnecting the memory.
8.9 Slowdown type selection:
The control unit can carry out two different types of slowdown:
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
8.10 Enabling / disabling the Encoder
The control unit was thought for being used with two motors equiped with encoder. It is possible to enable and disable the Encoder
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
NOTE: the encoder do not control the position of the gate. It is exclusively used for the detection of obstacles. We recommend to correctly adjust
the torque by combining it with the encoder in order to have an optimal functioning.
6-1622158 REV.03
25/09/2020
ON
Condominium function disabled
OFF
Condominium function enabled. Every impulse given by radio or by a step-by-step and/or pedestrian button
ON
OFF
causes only the opening of the automatism. The closing is carried out by the automatic reclosing function
(Dip 3 on ON), which must be enabled as every other closing impulse is ignored. We recommend to enable
also the open–close function with the dip 1 ON.
ON
The intervention of limit switches causes the stopping of the automation.
OFF
The intervention of limit switches causes the slowdown of the automation. This setting is recommended in
ON
OFF
case the automatism has mechanical limit switches.
ON
If you are using transmitters of the fix code series, then set the dip 8 on ON position and RESET the
OFF
memory.
ON
With a rolling code transmission you must set the dip 8 on OFF position and RESET the memory.
OFF
ON
This is the classic slowdown with reduction of torque.
OFF
The slowdown is carried out with double speed and higher torque. This is recommended for the moving of
ON
particularly heavy doors and gates. By enabling this function we recommend to have a wide area for the
OFF
slowdown as the position where the slowdown begins can slightly change from one motion to the next one.
ON
ENCODER disabled
OFF
ON
ENCODER enabled. With the encoder enabled the unit controls the progress of the gate and inverts the
OFF
run in case an obstacle is hit