7.2 For applications of motors with limit switches controlling the start of the slowdowns (DIP 7 on ON)
This procedure must be carried out ONLY by the installer and ONLY during the installation of the system. Always bring the gate to a totally closed
position before making any changements for a correct programming. During the learning phase the limit switches decide where the gate starts the
slowdown phase.
Dipswitch Position
ON
1
OFF
7
Press and keep pressed the
2
MODE button on the card
Press and release the SEL button
3
on the card.
Release the MODE button.
4
The learning is cancelled if one safety device (photocell, edge, stop) is activated during the learning phase
Follow these instructions once entered into the movement learning:
Give an impulse of step-by-step through the
5
button or the transmitter
When the gate reaches the opening limit
6
switch,
then
the
automatically.
When the automation reaches the desired
opening position, then press and release the
7
SEL (or MODE) button or give a step-by-step-
impulse.
Give a step-by-step impulse with te button or
8
with the transmitter
When the gate reaches the closing limit switch,
then the automatism slowdowns automatically.
9
When the automation reaches the desired
closing position, then press and release the
10
SEL (or MODE) button or give a step-by-step-
impulse.
11
The control unit blinks 3 times
8. Functions selectable by dip-switch
It is important to change the configuration of the dip-switches only when the card is turned off!
Remove the power supply during the configuration changing.
Default settings
The control board is supplied with the dip-switches set as listed below. The functions selectable by dip-switch are summarized into the following table.
6-1622158 REV.03
25/09/2020
Put the DIPSWITCH 7 on ON
automatism
slowdowns
N° dip
Function
1
Step-by-step
2
Photocells test
3
Automatic reclosing
4
Photocells functioning
5
Pre-blinking
6
Condominium function (Always Opens)
7
Limit switch operating mode
8
Reception mode
9
Torque and slowdowns speed
10
Encoder
ITA
The accessing to the automatism motion learning menu is shown by 1
Blink emitted by the flashing light
The automation starts to open
The automation works with a reduced speed.
The automation stops.
The automation starts to close
The automation works with a reduced speed.
The automation stops.
The learning is finished
Dip OFF
Open-stop-close
Active
Not active
Motion stop
Not active
Not active
Door stop
Rolling code
Normal
Not active
ENG
FRA
ESP
DEU
POR
Dip ON
Open-close
Not active
Active
Stop and reversal motion
Active
Active
Door Slowing down
Fixed code
Maximum
Active
7 / 16