8.1 Step by step function:
You can set the answer of the control unit to subsequential commands given by transmitter or by the step-by-step button:
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
The step-by-step impulse may be given both by a special input (see step-by-step button on the terminal board), or by pushing the first key of a
memorized transmitter (see learning transmitter paragraph).
8.2 Photocells test:
This control unit is supplied with a system which allows to carry out a test on the functioning of photocell before each operation of the motor. This oper-
ation increases the security system in case a photocell is damaged (for example if the output relay get stuck) or in case of a short circuit in the photo-
cell's input . This test is carried out after the control unit has received an impulse to move (closing or opening), and it gives power to the motor.
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
NOTE: If the photocells test is enabled, then the motor's start is delayed by approximately one second from when the input is received.
The control unit is settled for a single photocell input. However it is possible to connect up to 2 cou-
ples of photocells: in this case the Normally Closed contacts must be put in series as shown here on
the right:
8.3 Automatic re-closing:
If the automatic re-closing function is enabled, then it closes the automatism after a preset period of time.
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
8.4 Safety photocells:
When the beam between the transmitter's photocells and the receiver ones is interrupted, then the these last change the behavior of the control unit
according to the following modalities:
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
8.5 Pre-blinking function:
The flashing lights shows with a slow blinking (approximately 1 every 2 seconds) the opening of the automatism, and with a faster one (approximately
1 per second) the closing.
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
6-1622158 REV.03
25/09/2020
The automation carries out the open-stop-close-stop sequence.
The automation carries out an open-close-open-close sequence.
Photocells test enabled. The order is not executed in case the photocells are damaged.
Photocells test disabled.
Automatic re-closing not active. The automatism closes only with a closing impulse given by a step-by-step input or
by a recorded transmitter.
After the opening of the automatism, when the pause time expires, the door closes automatically. The preset stand-
ard time is 10 seconds. The function can be temporarily disconnected by stopping it with a step-by-step command.
See chapter 10.1 in order to change the time of automatic reclosing.
Automatism during the opening and closing cycle:
If the photocells detect an obstacle, then the control unit stops the automatism's motion. When the obstacle is re-
moved, then the motion starts again in OPENING until the end of its cycle.
A) Automatism during the opening cycle:
If the photocells detect an obstacle, then the control unit does not stop the automatism's motion.
B) Automatism during the closing cycle:
If the photocells detect an obstacle, then the control unit stops and inverts the motion by opening completely the
automatism.
Pre-flashing disabled
Pre-flashing enabled. A pre-flashing has the aim to indicate to the user that the automatism is going to move, and
this is why it comes before the automatism's motion. The time of the pre-flashing is set to 3 seconds.
ITA
ENG
FRA
ESP
DEU
POR
1 2 3
Foto1
Foto2
8 / 16