10. Advanced settings
10.1 Changing the automatic reclosing time
In case you want to enable this function, then put the dip-switch 3 on ON. The enabling sequence of this learning menu is the following:
1.
Press the MODE button and keep it pressed
2.
Press and release the SEL button twice, and then release the MODE button. The accessing to the learning menu of the pause time is shown
by 2 closed blinks of the flashing light.
3.
By pressing the MODE button you increase the reclosing time of about 10 seconds each time you press it, while by pressing the SEL button
you decrease the time of automatic reclosing by about 10 seconds each time your press it.
The factory value for the automatic closing time is approximately 10 seconds.
You must give a step-by-step impulse for leaving the learning phase.
10.2 Changing the water hammer activation of the electrical lock
The water hammer is disabled as default setting. The enabling sequence of this learning menu is the following:
1.
Close the automation with a step-by-step command
2.
Press the MODE button and keep it pressed while the automatism and the flashing lights are turned off
3.
Press the SEL button three times
4.
Release the MODE button
5.
The accessing to the learning menu of the water hammer is shown by 3 closed blinks of the flashing light.
6.
By pressing the MODE button you increase the water hammer time of about 0,1 seconds each time you press it, while by pressing the SEL
button you decrease the time of the water hammer by about 0,1 seconds each time your press it, until the default value is reached.
7.
You must give a step-by-step impulse for leaving the learning phase.
The use of water hammer is not recommended for sliding and bascule gates.
Set a minimum time of 0,3 seconds for enabling the water hammer in closing.
10.3 Changing the over-stroke time in opening and in closing
The time of over-stroke is the extension of the working time in opening and closing.
The enabling sequence of this learning menu is the following:
1.
Press the MODE button and keep it pressed.
2.
Press and release 4 times the SEL button.
3.
Release the MODE button. The accessing to the learning menu of the stroke time is shown by 4 closed blinks of the flashing light.
4.
By pressing the MODE button you increase the over-stroke time by about 10 seconds each time you press it, while by pressing the SEL button
you decrease the over-stroke by about 10 seconds each time your press it.
The factory value for the over-stroke time is set at about 4 seconds.
You must give a step-by-step impulse for leaving the learning phase.
10.4 Inversion time at the end of the motion
The inversion time at the end of the movement beyond the opening or closing limit switch, is a time where the control unit makes a short inversion for
relaxing the mechanics.
The enabling sequence of this learning menu is the following:
1.
Press the MODE button and keep it pressed
2.
Press and release 5 times the SEL button.
3.
Release the MODE button. The accessing to the learning menu of the inversion time is shown by 5 closed blinks of the flashing light.
4.
By pressing the MODE button you increase the inversion time by about 0,1 seconds each time you press it (the first pressing of the MODE key
sets an increase of the inversion time by 0,02 seconds), while by pressing the SEL button you decrease the inversion time by about 0,1
seconds each time your press it (the first pressing of the SEL key sets a decrease of the inversion time by 0,02 seconds).
The inversion at the end of the motion is disabled as factory default and after each reset of the control unit.
You must give a step-by-step impulse for leaving the learning phase.
NOTE: The activation of the inversion function disables the water hammer in closing
10.5 Enabling/Disabling the clock function
The clock function allows to open and to keep the gate open for a period of time. The gate automatically closes at the end of this period. The enabling
sequence of this learning menu is the following:
1.
Press the MODE button and keep it pressed
2.
Press and release 6 times the SEL button
3.
Release the MODE button. The accessing to the learning menu of the clock function is shown by 6 closed blinks of the flashing light
4.
Press the MODE or SEL for enabling/disabling this function. The LEARN led and the flashing light show that the function is enabled when they
are both ON FIX. If the led and flashing light are OFF, this means that the function is disabled.
You must give a step-by-step impulse for leaving the learning phase
Connect the clock contact to the step-by-step input of the control unit. This function is enabled if the contact remains closed for more than 15 seconds.
Once the function is active, every other impulse is ignored. The control unit leaves automatically the function and closes the gate when the contact
opens. The STOP intervention or another safety operation block the gate motion, and the control unit exits the clock modality.