5. Preliminary checks
The preliminary checks need to be carried out only by professionals paying maximum attention. The correct wiring of the motor and the limit
switches is very important for the correct working of the automatism.
After the cables has been controlled and that there are no
short circuits, unlock the motor and supply power to the
1
system.
Manually bring the gate to a totally open position and check
2
the status of the LS.OP led.
Manually bring the gate to a totally closed position and
3
check the status of the LS.CL led.
Manually bring the gate to the middle of the stroke. Make
4
sure that DIP 7 is set on OFF position. Give a step by step
impulse with the button or the transmitter .
Manually bring the gate to the middle of the stroke and then
relock the motor. Make sure that DIP7 is on OFF position.
5
Give a step by step command with the button or the
transmitter
WARNING: Be very careful with the moving gate
Once these tests have been successfully completed, close
6
the automation and relock the motor.
WARNINGS:
In case the position is not known when the control unit is turned on (i.e. it is not on a limit switch), the control unit makes the first motion slowly
until the gate reaches a switch limit (if the slowdowns are disconnected, then the stroke is carried out at a normal speed)
If both limit switches are enabled when they receive an impulse, then the control unit indicates the anomaly and does not make a move.
If the gate is not on a limit switch when the control unit is turned on, then it puts itself at the closing position. It is possible to carry out the learning
operations and modify the parameters as far as no maneuver is executed.
6-1622158 REV.03
25/09/2020
Check the input leds conditions by considering that all the
normally closed inputs need to have their corresponding
led turned on.
The motor turns on. Look at the flash. light and the learning led
If the motor doesn't stop, then activate the limit switch in
the opposite direction. The motor stops. Cut the power
supply to the system and invert the connections between 5
and 7. Repeat the test.
The motor turns on. Look at the flashing light or the learning led
and the motion of the gate
If the motion of the gate is wrong, then stop the
automation and invert the connections between 5 and 7.
Repeat all checks from the beginning.
ITA
ENG
FRA
ESP
DEU
POR
LS.OP led is turned off. The functioning is correct.
LS.OP led is turned on but LS.CL led is turned off. Invert
the connections between 5 and 7 and between 15 and 16.
LS.CL led is turned off. The functioning is correct.
LS.CL led is turned on but LS.OP led is turned off.
Check the connections and start again from point 2.
If the flashing is fast (1 blinking per second), then you
must activate the closing limit switch. The motor stops.
If the flashing is slow (1 blinking every 2 seconds),
then you must activate the opening limit switch. The
motor stops.
If the flashing is fast (1 blinking per second) then the
gate must close.
If the flashing is slow (1 blinking every 2 seconds)
then the gate must open.