Télécharger Imprimer la page

Setting The Rotational Speed Of The Ventilator Levels - Pluggit Avent AP190 Manuel D'utilisation Et D'installation

Publicité

Les langues disponibles

Les langues disponibles

About Pluggit iFlow
1. Activating Pluggit iFlow, see page 17.
2. Follow the instructions of the Pluggit iFlow and switch in
or off the installer menu.
4.6.5.
Setting the rotational speed of the ventilator
levels
The rotational speed of the ventilator levels can be set using
the control unit at the room ventilation unit or using the
Pluggit iFlow.
Before setting the rotational speeds, the condensate line
must be installed and the correct draining of the water must
be checked, see page 16.
All set values must be filled in the section "Start- and oper-
ating information", see page 25.
Setting range for the rotational speed of the ventilator
levels, see page 27.
About control unit
2
3
1
1. Remove designer cover (1).
2. Unscrew screws (2) and remove front cover (3).
18
OII Avent P190/P310/P460
3. Loosen rubber plug from the connectors (4) and connect
2
4. Press buttons (5) and (6) until the LEDs (7) start flashing.
M+P-26A-0925
5. Hold down button (8) and press button (5) to decrease or
4
9
differential pressure gauge diagonally.
8
5
7
6
The installer menu is switched on and the ventilators
accelerate to level 3.
All other device features are disabled.
button (6) to increase the rotational speed of the ventilator.
The rotational speed of the right ventilator can be set
according to the chart (9).
4
M+P-26A-0893
M+P-26A-0894

Publicité

loading

Ce manuel est également adapté pour:

Avent ap310Avent ap460