17
16. Start laptop.
17. Plug the USB cable with port type A in the laptop and
port type B in USB interface (17).
18. Start Pluggit iFlow.
Note:
The Pluggit iFlow can be downloaded free of charge at
www.pluggit.com and installed on the laptop. For this
purpose, you need to register as user/specialised com-
pany.
19. Open installer section using the password.
The password is available after successful registration.
20. If the room ventilation unit is not automatically detected,
enter serial number and save it, see operating and in-
stallation instructions of the room ventilation unit.
21. Follow the instructions of the Pluggit iFlow and set T
and T
.
max
T
between 8-15 °C
min
T
between18-30 °C.
max
4. TECHNICAL DATA
Engine: CM230-1-T0-L DAN
2Nm/18in-lb
230VAC 50Hz
75s / 90×
8,5VA 1,5W
IP54
5. DECOMMISSIONING/DISPOSAL
5.1. DECOMMISSIONING IN CASE OF DISMANTLING
M+P-26A-0914
Decommissioning must only be carried out by qualified ex-
pert personnel.
• Disconnect the unit from power supply.
• Disconnect all poles of the unit from the power supply
system.
5.2. PACKAGING
The transport and protective packaging are usually manu-
factured from reusable materials.
All packaging material must be disposed of according to
local laws and regulations.
5.3. OLD APPLIANCE
The bypass contains valuable materials and substances
which should be kept separate from residual waste.
The old appliance can be delivered to the local recycling
company for recycling.
min
II bypass for Avent P190/P310/P460
5