5.7. SWITCHING OH/OFF THE FIRE BOOSTER

When initiating a fireplace, such as a fireside, the fire
booster must be switched on.
With the fire booster switched on, the supply air ventilator is
set to level 3. The room ventilation unit operates at the nom-
inal volume flow rate. The supply air ventilator operates at
a speed of 100 % and the exhaust air ventilator at a speed of
50 %.
If the supply air temperature (T2) falls below 9 °C before the
period of 7 minutes has expired, the room ventilation unit
automatically switches back to the last operating mode. The
unit operates again at the speed of the previous operating
mode.
About control unit
1
2
Hold down button (1) for approx. 4 seconds.
The fire booster is switched on for 7 minutes.
Three LEDs (2) flash.
After the time has expired, the room ventilation unit auto-
matically switches back to the last operating mode.
About Pluggit iFlow
1. Activating Pluggit iFlow, see page 36.
2. Follow the instructions of the Pluggit iFlow and switch
on or off the fire booster.

5.8. RESET FILTER ALARM

The filter alarm must be reset after each filter change.
About control unit
If the preset time interval for the filter change has been ex-
ceeded or if a filter change has been generated by the Ser-
voFlow (accessory), the LED (1) lights orange.
The filters must be replaced, see page 46.
If the preset time interval has been exceeded for more than
90 days or if the calibration of the ServoFlow does not work
properly, the LED (1) lights red. The nominal volume flow
rate can no longer be attained and the room ventilation unit
switches off.
Press button (2) for approx. 10 seconds.
M+P-26A-0902
The filter alarm has been reset.
Note:
The LED (1) will illuminate after 12 months as default.
Thus, the timer for the filter alarm can also be reset
without replacing the filter if required.
About Pluggit iFlow
1. Activating Pluggit iFlow, see page 36.
2. Follow the instructions of the Pluggit iFlow and reset the
filter alarm.