2
Operation
➅
Now enter the following two-digit
number at the 10-button keypad
on the Control Unit:
Locomotive address:
01
Minimum speed:
02
Acceleration delay:
03
Braking delay:
04
Maximum speed:
05
Volume:
63
When you have entered it correctly,
this value can now be seen in the
address display for the Control Unit.
➆
Confirm the entry by activating the
direction reversing function. The
locomotive confirms the entry of the
address, when the headlights blink
twice.
24
➅
01
2
1
Example:
Setting the new loco-
motive address "10"
➆
01
1
➇
Now enter the value for the new
parameter as a two-digit number.
The following values are possible
individually:
Locomotive address: 01 to 80
(value corresponds to the desired
address).
Minimum speed: 01 to 63.
The higher the value, the higher the
voltage in the lowest speed level. If
the value selected is too small, the
locomotive will not run until a higher
speed level is chosen with the speed
control knob.
Acceleration delay: 01 to 63.
A value of 01 means no discernible
acceleration delay. 63 means the
maximum acceleration delay (just
55 seconds!).
Braking delay: 01 to 63.
A value of 01 means no discernible
braking delay. 63 means the maximum
braking delay (just 55 seconds!).
Maximum speed: 01 to 63.
A value of 01 means the maximum
speed that can be set for this model.
63 means the maximum speed that
can be set for this model.
Volume: 01 – 63
01 = soft
63 = loud
➇
1
10
2