Maintenance,Troubleshooting
Installing the adjusting screws (Pos. 02):
Fig. 17: Installing the adjusting screws
→
Insert the adjusting screws (Pos. 02), the nuts (Pos. 04), the
washers (Pos. 03) and the O-rings,
→
Screw the adjusting screws (Pos. 02) into the housing.
End position setting for the standard actuator (closing
clockwise):
→
0° (closing) end position setting, for actuator in closed position
unscrew the right adjusting screw until the required end position
is reached. Secure by tightening the nut (Pos. 04).
→
90° (opening) end position setting, unscrew the left adjusting screw
until the required end position is reached. Secure by tightening
the nut (Pos. 04).
Type 2051
02
Installing the graduated collar and the position indicator (Pos.
19, 19.0, 19.1):
Fig. 18: Placing graduated collar on the housing
→
Place the graduated collar (Pos. 19.0) on the housing,
→
Align adapter (Pos. 19.5) and secure with suitable screws (Pos.
19.6),
→
Insert position indicator (Pos. 19 or 19.1),
→
Screw in the screw (Pos.39) for the position indicator.
19.5
19.1
19.6
Fig. 19: Installing the graduated collar and the position indicator
english
39
19
23